Litcius/Paper detail

Silver nanoparticle-modified electrodes for the electrochemical detection of neonicotinoid pesticide: clothianidin

A. Kumaravel

2022Analytical Methods15 citationsDOI

Abstract

Ag/AgCl on the silver nanoparticle-modified electrode, whereas no reduction peak was observed on a bare glassy carbon electrode (GCE). The detection limit was found to be 2.4 nM. The reduction potential and detection limits reported in this work are lower than ever reported in the literature. The analytical validity of clothianidin was tested using tomatoes. Validation of electrochemical results has been achieved by comparing them to HPLC results. There is a good agreement between the results and those obtained by HPLC. The proposed sensor opens up new possibilities for the sensing of clothianidin in environmental samples.

Topics & Concepts

ClothianidinDetection limitElectrodeElectrochemistryMaterials scienceSilver nanoparticleNeonicotinoidChromatographyNanoparticleChemistryNanotechnologyNuclear chemistryPesticideThiamethoxamAgronomyPhysical chemistryImidaclopridBiologyInsect and Pesticide ResearchPesticide Residue Analysis and SafetyElectrochemical Analysis and Applications