Litcius/Paper detail

Local control and toxicity after magnetic resonance imaging (MR)-guided single fraction lung stereotactic ablative radiotherapy

H. Tekatli, M. Palacios, Famke L. Schneiders, Cornelis J.A. Haasbeek, Ben J. Slotman, Frank J. Lagerwaard, Suresh Senan

2023Radiotherapy and Oncology10 citationsDOIOpen Access PDF

Abstract

PURPOSE: Magnetic resonance imaging (MR)-guided radiotherapy permits continuous intrafraction visualization and use of automatic triggered beam delivery, with use of smaller planning target volumes (PTV). We report on long-term clinical outcomes following MR-guided single fraction (SF) lung SABR on a 0.35 T linac. MATERIALS AND METHODS: Details of patients treated with SF-SABR for lung tumors were accessed from an ethics approved institutional database. A breath-hold 3D MR simulation scan was performed using a true FISP sequence, followed by a breath-hold 3D CT scan. The gross tumor volume (GTV) was first contoured on the breath-hold CT scan, which was then compared with contours on the 3D MR scan, before the GTV was finalized. SABR plans used step-and-shoot IMRT beams to a PTV derived by adding a 5 mm margin to the breath-hold GTV, and a 3 mm gating window was used. SABR was delivered during repeated breath-holds, using automatic beam gating with continuous visualization of the GTV in a sagittal MR plane. RESULTS: Between 2018-2022, 50 consecutive patients were treated, and 69% had a primary non-small cell lung cancer. Median PTV was 11.2 cc (range 3.9-53.5); 80% of GTV's were located ≤2.5 cm from the chest wall. Prescribed doses were 34 Gy (in 58%), 30 Gy (32%), or between 20-28 Gy (10%). After a median follow-up of 18.1 months (95% CI 12.8-23.5), the 2-year survival was 82% (89% for primary NSCLC and 62% for metastases). After a median follow-up of 16.1 months (95% CI 11.2-21.1), local recurrences developed in 2 patients (4%). The 3-year local control rate was 97%, and just 1 patient developed grade ≥3 toxicity (chest wall pain). CONCLUSION: MR-guided SF-SABR delivery to lung tumors on a 0.35 T linac, using repeated breath-holds with automatic beam gating, achieves good tumor control and low toxicity.

Topics & Concepts

SABR volatility modelMedicineNuclear medicineAblative caseMagnetic resonance imagingRadiosurgeryLung cancerRadiation therapyRadiologyLungSagittal planePathologyInternal medicineVolatility (finance)EconomicsFinancial economicsStochastic volatilityAdvanced Radiotherapy TechniquesLung Cancer Diagnosis and TreatmentHepatocellular Carcinoma Treatment and Prognosis