Litcius/Paper detail

Fast and high-resolution X-ray nano tomography for failure analysis in advanced packaging

Till Dreier, Daniel Nilsson, Julius Hållstedt

2025Microelectronics Reliability7 citationsDOIOpen Access PDF

Abstract

Advanced packaging in electronics involves integrating semiconductor devices and sensors into a unified package, often employing complex 3D structures for enhanced performance and efficiency. As electronic components become smaller and more densely packed, conventional 2D X-ray radiography is not sufficient for inspection. Here we demonstrate the use of nano-CT with a high bandwidth memory (HBM) example illustrating the potential of fast detection of sub-micron voids and cracks in micro-bumps. Using a 30 s overview scan at 2.6 μm voxel size for navigation, a region is selected for a high-resolution scan with a voxel size of 600 nm to analyse 20 μm micro-bumps in between DRAM layers. Additionally, high-resolution laminography is performed showing the differences of the 2 techniques. The results show how high-resolution nano-CT can effectively be used for fast failure analysis and R&D as well as important feedback to production ramp up and yield improvements of advanced packaging technologies.

Topics & Concepts

Nano-Resolution (logic)TomographyMaterials scienceX-rayHigh resolutionNanotechnologyComputer scienceOpticsPhysicsArtificial intelligenceComposite materialRemote sensingGeologyIntegrated Circuits and Semiconductor Failure AnalysisElectron and X-Ray Spectroscopy TechniquesIon-surface interactions and analysis
Fast and high-resolution X-ray nano tomography for failure analysis in advanced packaging | Litcius