A Comparison Study of Posture and Fatigue of Neck According to Monitor Types (Moving and Fixed Monitor) by Using Flexion Relaxation Phenomenon (FRP) and Craniovertebral Angle (CVA)

Kyeong‐Hee Choi, Min-Uk Cho, Chaewon Park, Seoung-Yeon Kim, Minjung Kim, Boram Hong, Yong‐Ku Kong

2020International Journal of Environmental Research and Public Health29 citationsDOIOpen Access PDF

Abstract

This study quantified the neck posture and fatigue using the flexion relaxation phenomenon (FRP) and craniovertebral angle (CVA); further, it compared the difference between the level of fatigue and neck posture induced by two types of monitors (regular fixed monitor and moving monitor). Twenty-three male participants were classified into two groups-the low-flexion relaxation ratio (FRR) group and the normal-FRR group, depending on the FRR value. All participants performed a document task for 50 min using both types of monitors. It was found that the FRR values significantly decreased after the documentation task. The CVA analysis showed that the moving monitor's frequency of forward head posture (FHP) was lower than that for the fixed monitor. Overall, the moving monitor worked better than the fixed monitor; this can be interpreted as proof that such monitors can reduce neck fatigue.