Strain Measurement with Optic Fibers for Structural Health Monitoring of Woven Composites: Comparison with Strain Gauges and Digital Image Correlation Measurements

Carlo Boursier Niutta, Andrea Tridello, Raffaele Ciardiello, Davide Salvatore Paolino

2023Sensors13 citationsDOIOpen Access PDF

Abstract

In this work, the strains measured with optic fibers and recorded during tensile tests performed on carbon/epoxy composite specimens were compared to those recorded by strain gauges and by Digital Image Correlation (DIC). The work aims at investigating the sensitivity of embedded and glued optic sensors for structural health monitoring applications in comparison with strain gauges and the full field strain map of the DIC. Acrylate, polyimide optic fibers, and three strain gauge sizes are considered to compare the three techniques. Results show hard polyimide-coated sensors are more sensitive to the material pattern than soft acrylate-coated fibers, which also require extensive adhesion length. The work shows a comparable size of strain gauges and material meso-structure is also critical for properly assessing material properties. The Young's modulus computed with the three different techniques is used to define a strategy that supports the selection and the proper size of the adopted strain measuring system for structural health monitoring of composite materials.

Topics & Concepts

Digital image correlationStrain gaugeMaterials scienceComposite materialStructural health monitoringStrain (injury)Composite numberOptical fiberGauge factorModulusEpoxyPolyimideOpticsAlternative medicineInternal medicinePhysicsPathologyMedicineFabricationLayer (electronics)Advanced Fiber Optic SensorsStructural Health Monitoring TechniquesOptical measurement and interference techniques