Dual-wavelength responsive photoelectrochemical aptasensor based on ionic liquid functionalized Zn-MOFs and noble metal nanoparticles for the simultaneous detection of multiple tumor markers
Yingying Zhong, Xian Wang, Ruyan Zha, Chen Wang, Huijuan Zhang, Yanying Wang, Chunya Li
Abstract
(S/N = 3), respectively. CA153 and CEA in serum samples were detected by the PEC aptasensor, and their concentrations were well consistent with that obtained from the ELISA. In addition, the PEC aptasensor exhibited a recovery rate of 96.98%-103.4%, and a relative standard deviation of 1.1%-3.6%, indicating good practical value and accuracy, further confirming its potential for clinical diagnosis.
Topics & Concepts
AptamerNoble metalNanoparticleDetection limitChemistryMaterials scienceColloidal goldIonic bondingMetalChromatographyNanotechnologyIonMolecular biologyBiologyOrganic chemistryAdvanced biosensing and bioanalysis techniquesGold and Silver Nanoparticles Synthesis and ApplicationsBiosensors and Analytical Detection