Litcius/Paper detail

18F-Fluorocholine PET and Multiphase CT Integrated in Dual Modality PET/4D-CT for Preoperative Evaluation of Primary Hyperparathyroidism

Valentin Pretet, Marianela Rotania, Mehdi Helali, Mihaela Ignat, Michel Vix, Alessio Impériale

2020Journal of Clinical Medicine34 citationsDOIOpen Access PDF

Abstract

The present retrospective study evaluates the diagnostic value of integrated 18F-Fluorocholine positron emission tomography/four-dimensional contrast-enhanced computed tomography (18F-FCH PET/4D-CT) as second-line imaging in preoperative work-up of primary hyperparathyroidism (pHPT), and compares 18F-FCH PET with 4D-CT. Patients with pHPT and negative/discordant first-line imaging addressed for integrated 18F-FCH PET/4D-CT were retrospectively selected. Sensitivity and detection rate (DR%) of 18F-FCH PET/CT, 4D-CT, and PET/4D-CT were calculated according to the per patient and per lesion analyses, and afterwards compared. Histology associated with a decrease more than 50% of perioperative parathyroid hormone (PTH) blood level was used as a gold standard. Persistent high serum PTH and calcium levels during a 6-month follow-up was considered as presence of pHPT in both operated and non-operated patients. 50 patients (55 glands) were included. 44/50 patients (88%) were surgically treated. On a per patient analysis, sensitivity was 93%, 80%, and 95%, and DR% was 82%, 68%, and 84%, respectively for PET/CT, 4D-CT, and PET/4D-CT. PET/CT was more sensitive than 4D-CT (p = 0.046). PET/4D-CT performed better than 4D-CT (p = 0.013) but was equivalent to PET/CT alone. On a per gland analysis, sensitivity PET/CT, 4D-CT, and PET/4D-CT was 88%, 66%, and 92%, and DR% was 79%, 57%, and 83%, respectively. PET/CT and PET/4D-CT were more sensitive than 4D-CT alone (p = 0.01, p < 0.001, respectively). However, PET/CT and PET/4D-CT performed similarly. In conclusion, 18F-FCH PET provides better identification of hyperfunctioning parathyroids than 4D-CT and the combination of both did not significantly improve diagnostic sensitivity. Further investigations involving larger populations are necessary to define the role of 18F-FCH PET/4D-CT as a “one-stop shop” second-line imaging in preoperative work-up of pHPT, especially considering the additional patient radiation exposure due to multi-phase CT.

Topics & Concepts

MedicinePrimary hyperparathyroidismPET-CTRadiologyNuclear medicineModality (human–computer interaction)HyperparathyroidismComputed tomographyInternal medicineArtificial intelligenceComputer scienceParathyroid Disorders and TreatmentsThyroid and Parathyroid SurgeryBone health and osteoporosis research
18F-Fluorocholine PET and Multiphase CT Integrated in Dual Modality PET/4D-CT for Preoperative Evaluation of Primary Hyperparathyroidism | Litcius