Litcius/Paper detail

Anticipation of Historical Exercise Patterns by a Novel Artificial Pancreas System Reduces Hypoglycemia During and After Moderate-Intensity Physical Activity in People with Type 1 Diabetes

José Garcia‐Tirado, Sue A. Brown, Nitchakarn Laichuthai, Patricio Colmegna, Chaitanya L.K. Koravi, Başak Özaslan, John P. Corbett, Charlotte L. Barnett, Michael Pajewski, Mary Oliveri, Helen E. Myers, Marc D. Breton

2020Diabetes Technology & Therapeutics45 citationsDOIOpen Access PDF

Abstract

Objective: Physical activity is a major challenge to glycemic control for people with type 1 diabetes. Moderate-intensity exercise often leads to steep decreases in blood glucose and hypoglycemia that closed-loop control systems have so far failed to protect against, despite improving glycemic control overall. Research Design and Methods: Fifteen adults with type 1 diabetes (42 ± 13.5 years old; hemoglobin A 1c 6.6% ± 1.0%; 10F/5M) participated in a randomized crossover clinical trial comparing two hybrid closed-loop (HCL) systems, a state-of-the-art hybrid model predictive controller and a modified system designed to anticipate and detect unannounced exercise (APEX), during two 32-h supervised admissions with 45 min of planned moderate activity, following 4 weeks of data collection. Primary outcome was the number of hypoglycemic episodes during exercise. Continuous glucose monitor (CGM)-based metrics and hypoglycemia are also reported across the entire admissions. Results: The APEX system reduced hypoglycemic episodes overall (9 vs. 33; P = 0.02), during exercise (5 vs. 13; P = 0.04), and in the 4 h following (2 vs. 11; P = 0.02). Overall CGM median percent time <70 mg/dL decreased as well (0.3% vs. 1.6%; P = 0.004). This protection was obtained with no significant increase in time >180 mg/dL (18.5% vs. 16.6%, P = 0.15). Overnight control was notable for both systems with no hypoglycemia, median percent in time 70–180 mg/dL at 100% and median percent time 70–140 mg/dL at ∼96% for both. Conclusions: A new closed-loop system capable of anticipating and detecting exercise was proven to be safe and feasible and outperformed a state-of-the-art HCL, reducing participants' exposure to hypoglycemia during and after moderate-intensity physical activity. ClinicalTrials.gov NCT03859401.

Topics & Concepts

MedicineHypoglycemiaGlycemicArtificial pancreasCrossover studyDiabetes mellitusType 1 diabetesType 2 diabetesContinuous glucose monitoringInternal medicineEndocrinologyPlaceboPathologyAlternative medicineDiabetes Management and ResearchPancreatic function and diabetesDiabetes and associated disorders