MITIGATE-NeoBOMB1, a Phase I/IIa Study to Evaluate Safety, Pharmacokinetics, and Preliminary Imaging of <sup>68</sup>Ga-NeoBOMB1, a Gastrin-Releasing Peptide Receptor Antagonist, in GIST Patients

Leonhard Gruber, Luis David Jiménez‐Franco, Clemens Decristoforo, Christian Uprimny, Gerhard Glatting, Peter Hohenberger, Stefan O. Schoenberg, Wolfgang Reindl, Francesca Orlandi, Maurizio Mariani, Werner Jaschke, Irene Virgolini

2020Journal of Nuclear Medicine60 citationsDOIOpen Access PDF

Abstract

Gastrin-releasing peptide receptors (GRPRs) are potential molecular imaging targets in a variety of tumors. Recently, a <sup>68</sup>Ga-labeled antagonist to GRPRs, NeoBOMB1, was developed for PET. We report on the outcome of a phase I/IIa clinical trial (EudraCT 2016-002053-38) within the EU-FP7 project Closed-loop Molecular Environment for Minimally Invasive Treatment of Patients with Metastatic Gastrointestinal Stromal Tumors (‘MITIGATE’) (grant agreement no. 602306) in patients with oligometastatic gastrointestinal stromal tumors (GIST). <b>Methods:</b> The main objectives were evaluation of safety, biodistribution, dosimetry, and preliminary tumor targeting of <sup>68</sup>Ga-NeoBOMB1 in patients with advanced tyrosine-kinase inhibitors–treated GIST using PET/CT. Six patients with histologically confirmed GIST and unresectable primary lesion or metastases undergoing an extended protocol for detailed pharmacokinetic analysis were included. <sup>68</sup>Ga-NeoBOMB1 was prepared using a kit procedure with a licensed <sup>68</sup>Ge/<sup>68</sup>Ga generator. <sup>68</sup>Ga-NeoBOMB1 (3 MBq/kg of body weight) was injected intravenously, and safety parameters were assessed. PET/CT included dynamic imaging at 5, 11, and 19 min as well as static imaging at 1, 2, and 3–4 h after injection for dosimetry calculations. Venous blood samples and urine were collected for pharmacokinetic analysis. Tumor targeting was assessed on a per-lesion and per-patient basis. <b>Results:</b><sup>68</sup>Ga-NeoBOMB1 (50 μg) was prepared with high radiochemical purity (yield &gt; 97%). Patients received 174 ± 28 MBq of the radiotracer, which was well tolerated in all patients over a follow-up period of 4 wk. Dosimetry calculations revealed a mean effective dose of 0.029 ± 0.06 mSv/MBq, with the highest organ dose to the pancreas (0.274 ± 0.099 mSv/MBq). Mean plasma half-life was 27.3 min with primarily renal clearance (mean 25.7% ± 5.4% of injected dose 4 h after injection). Plasma metabolite analyses revealed high stability; metabolites were detected only in the urine. In 3 patients, a significant uptake with increasing maximum SUVs (SUV<sub>max</sub> at 2 h after injection: 4.3–25.9) over time was found in tumor lesions. <b>Conclusion:</b> This phase I/IIa study provides safety data for <sup>68</sup>Ga-NeoBOMB1, a promising radiopharmaceutical for targeting GRPR-expressing tumors. Safety profiles and pharmacokinetics are suitable for PET imaging, and absorbed dose estimates are comparable to those of other <sup>68</sup>Ga-labeled radiopharmaceuticals used in clinical routine.

Topics & Concepts

GiSTBiodistributionPharmacokineticsNuclear medicineMedicineStromal tumorDosimetryStromal cellInternal medicineChemistryIn vitroBiochemistryGastrointestinal Tumor Research and TreatmentNeuroendocrine Tumor Research AdvancesPeptidase Inhibition and Analysis