Combined Impact of Asymmetric Critical Current and Flux Diverters on AC Loss of a 6.5 MVA/25 kV HTS Traction Transformer

Yue Wu, Wenjuan Song, Stuart C. Wimbush, Jin Fang, Rodney A. Badcock, Nicholas J. Long, Zhenan Jiang

2022IEEE Transactions on Transportation Electrification17 citationsDOIOpen Access PDF

Abstract

A 6.5 MVA/25 kV high-temperature superconducting (HTS) transformer for the Chinese Fuxing high-speed train has been proposed to replace the oil-based transformers while achieving higher efficiency, lighter weight, and minimized volume. The high targeted efficiency (>99%) makes ac loss reduction a vital issue. HTS coated conductors generally exhibit asymmetric critical current characteristics as a function of magnetic field angle <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$I_{c}$ </tex-math></inline-formula> ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$B$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\theta$ </tex-math></inline-formula> ), leading to a nontrivial influence on the ac loss of coil windings. The fast computing <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> – <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$A$ </tex-math></inline-formula> homogenization method is proposed to calculate the ac loss of the 6.5 MVA/25 kV traction transformer with large turn numbers. The variables, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$T$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$A$ </tex-math></inline-formula> , are the current and magnetic vector potentials, respectively. The ac loss of the transformer windings is analyzed for various coil configurations with and without flux diverters considering <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$I_{c}$ </tex-math></inline-formula> ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$B$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\theta$ </tex-math></inline-formula> ). At the rated current and 65 K, employing the flux diverters with a square-shape cross section, the total ac loss is decreased by 73.7% and an extra 150-W loss reduction was also obtained. Moreover, an additional reduction of 37 W is realized upon utilizing the asymmetric <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$I_{c}$ </tex-math></inline-formula> ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$B$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\theta$ </tex-math></inline-formula> ) characteristic. The reduced 187 W in ac loss at 65 K corresponds to a reduction in ambient power requirement of over 5.6 kW. Therefore, considering asymmetric <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$I_{c}$ </tex-math></inline-formula> ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$B$ </tex-math></inline-formula> , <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\theta$ </tex-math></inline-formula> ) can lead to a nontrivial reduction in ac loss, even incorporating flux diverters.

Topics & Concepts

NotationTransformerElectromagnetic coilMathematicsDiscrete mathematicsElectrical engineeringAlgorithmArithmeticEngineeringVoltagePhysics of Superconductivity and MagnetismHVDC Systems and Fault ProtectionSuperconducting Materials and Applications
Combined Impact of Asymmetric Critical Current and Flux Diverters on AC Loss of a 6.5 MVA/25 kV HTS Traction Transformer | Litcius