Carbon fiber–reinforced PEEK spinal implants for primary and metastatic spine tumors: a systematic review on implant complications and radiotherapy benefits
Hammad A. Khan, Roee Ber, Sean N. Neifert, David B. Kurland, Ilya Laufer, Douglas Kondziolka, Arpit M. Chhabra, Anthony Frempong‐Boadu, Darryl Lau
Abstract
OBJECTIVE: By minimizing imaging artifact and particle scatter, carbon fiber-reinforced polyetheretherketone (CF-PEEK) spinal implants are hypothesized to enhance radiotherapy (RT) planning/dosing and improve oncological outcomes. However, robust clinical studies comparing tumor surgery outcomes between CF-PEEK and traditional metallic implants are lacking. In this paper, the authors performed a systematic review of the literature with the aim to describe clinical outcomes in patients with spine tumors who received CF-PEEK implants, focusing on implant-related complications and oncological outcomes. METHODS: A systematic review of the literature published between database inception and May 2022 was performed in accordance with the 2020 Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The PubMed database was queried using the terms "carbon fiber" and "spine" or "spinal." The inclusion criteria were articles that described patients with CF-PEEK pedicle screw fixation and had a minimum of 5 patients. Case reports and phantom studies were excluded. RESULTS: This review included 11 articles with 326 patients (237 with CF-PEEK-based implants and 89 with titanium-based implants). The mean follow-up period was 13.5 months, and most tumors were metastatic (67.1%). The rates of implant-related complications in the CF-PEEK and titanium groups were 7.8% and 4.7%, respectively. The rate of pedicle screw fracture was 1.7% in the CF-PEEK group and 2.4% in the titanium group. The rates of reoperation were 5.7% (with 60.0% because of implant failure or junctional kyphosis) and 4.8% (all because of implant failure or junctional kyphosis) in the CF-PEEK and titanium groups, respectively. When reported, 72.5% of patients received postoperative RT (41.0% stereotactic body RT, 30.8% fractionated RT, 25.6% proton, 2.6% carbon ion). Four articles suggested that implant artifact was reduced in the CF-PEEK group. Local recurrence occurred in 14.4% of CF-PEEK and 10.7% of titanium-implanted patients. CONCLUSIONS: While CF-PEEK harbors similar implant failure rates to traditional metallic implants with reduced imaging artifact, it remains unclear whether CF-PEEK implants improve oncological outcomes. This study highlights the need for prospective, direct comparative clinical studies.