Litcius/Paper detail

Broadband Dielectric Spectroscopy: A Viable Technique for Aging Assessment of Low-Voltage Cable Insulation Used in Nuclear Power Plants

Davide Fabiani, Simone Vincenzo Suraci

2021Polymers36 citationsDOIOpen Access PDF

Abstract

This paper deals with the study of a non-destructive technique to detect the aging state of cable insulation used in a nuclear environment subjected to radiation and temperature aging. Cable samples were aged under dose rates ranging from 0.42 and 1.06 kGy/h at 55 and 85 °C. The imaginary part of the permittivity at 100 kHz is found to correlate well with mechanical properties, such as elongation at break, which is typically used to diagnose cable insulation, but it is a destructive property and cannot be used on field. It has been demonstrated also that a post-irradiation effect occurs even years after aging is stopped, increasing the imaginary permittivity and worsening mechanical properties due to the slow conversion of radicals into oxidized species. The main consequence is that when cable insulation is subjected to a nuclear accident, releasing a huge amount of radiation, the health of cable insulation must be followed also for a long time after the accident occurred, since aging due to oxidation progresses even when the radiation source is switched off.

Topics & Concepts

Materials scienceComposite materialPermittivityBroadbandDielectricRadiationIrradiationElongationAccelerated agingForensic engineeringElectrical engineeringOptoelectronicsOpticsTelecommunicationsComputer scienceEngineeringUltimate tensile strengthNuclear physicsPhysicsHigh voltage insulation and dielectric phenomenaElectrical Fault Detection and ProtectionConcrete Corrosion and Durability
Broadband Dielectric Spectroscopy: A Viable Technique for Aging Assessment of Low-Voltage Cable Insulation Used in Nuclear Power Plants | Litcius