Litcius/Paper detail

Ultrasensitive and simultaneous detection of 6 nonsteroidal anti-inflammatory drugs by colloidal gold strip sensor

Lu Lin, Liguang Xu, Hua Kuang, Jing Xiao, Chuanlai Xu

2021Journal of Dairy Science17 citationsDOIOpen Access PDF

Abstract

In this work, an oxicam group–selective monoclonal antibody against 6 nonsteroidal anti-inflammatory drugs (NSAID; meloxicam, lornoxicam, piroxicam, sudoxicam, droxicam, and tenoxicam) was prepared. Also, a spacer arm with carboxyl group was derived at the hydroxyl of meloxicam to generate the meloxicam hapten. The half-maximal inhibitory concentrations (IC50) were, respectively, 0.31 ng/mL for meloxicam, 0.49 ng/mL for lornoxicam, 2.90 ng/mL for piroxicam, 1.95 ng/mL for sudoxicam, 3.08 ng/mL for droxicam, and 5.36 ng/mL for tenoxicam. A colloidal gold immunochromatographic strip based on the monoclonal antibody was developed for the detection of these 6 NSAID in milk. The results could be obtained by the naked eye in 10 min, and the cut-off values and the visual limits of detection in real samples were 5, 5, 10, 10, 25, and 25 ng/mL, and 0.25, 1, 0.5, 0.5, 1, and 1 ng/mL, respectively. This immunochromatopgraphic strip is a suitable tool for on-site detection and screening of oxicam NSAID in milk samples.

Topics & Concepts

MeloxicamPiroxicamTenoxicamLornoxicamChemistryAnti-inflammatoryNonsteroidalChromatographyImmunoassayPharmacologyDetection limitAnalgesicMedicineAntibodyImmunologyAlternative medicinePathologyBiosensors and Analytical DetectionAdvanced biosensing and bioanalysis techniquesPharmacological Effects and Assays