Litcius/Paper detail

Prolonged PR interval and incidence of atrial fibrillation, heart failure admissions, and mortality in patients with implanted cardiac devices: A real-world survey

Hirad Yarmohammadi, Elaine Y. Wan, Angelo Biviano, Hasan Garan, Jodi Koehler, Robert Stadler

2022Heart Rhythm O213 citationsDOIOpen Access PDF

Abstract

BackgroundProlongation of the PR interval has long been considered a benign condition, particularly in the setting of nonstructural heart disease.ObjectiveThe purpose of this study was to investigate the effect of PR interval on various well-adjudicated cardiovascular outcomes using a large real-world population data of patients with implanted dual-chamber permanent pacemakers or implantable cardioverter-defibrillators.MethodsPR intervals were measured during remote transmissions in patients with implanted permanent pacemakers or implantable cardioverter-defibrillators. Study endpoints (time to the first occurrence of AF, heart failure hospitalization [HFH], or death) were obtained between January 2007 and June 2019 from the deidentified Optum de-identified Electronic Health Record dataset.ResultsA total of 25,752 patients (age 69.3 ± 13.9 years; 58% male) were evaluated. The average intrinsic PR interval was 185 ± 55 ms. In the subset of 16,730 patients with available long-term device diagnostic data, a total of 2555 (15.3%) individuals developed AF during 2.59 ± 2.18 years of follow-up. The incidence of AF was significantly higher (up to 30%) in patients with a longer PR interval (ie, PR interval ≥270 ms; P < .05). Time-to-event survival analysis and multivariable analysis showed that PR interval ≥190 ms was significantly associated with higher incidence of AF, HFH, or HFH or death when compared with shorter PR intervals (P < .05 for all 3 parameters).ConclusionIn a large real-world population of patients with implanted devices, PR interval prolongation was significantly associated with increased incidence of AF, HFH, or death. Prolongation of the PR interval has long been considered a benign condition, particularly in the setting of nonstructural heart disease. The purpose of this study was to investigate the effect of PR interval on various well-adjudicated cardiovascular outcomes using a large real-world population data of patients with implanted dual-chamber permanent pacemakers or implantable cardioverter-defibrillators. PR intervals were measured during remote transmissions in patients with implanted permanent pacemakers or implantable cardioverter-defibrillators. Study endpoints (time to the first occurrence of AF, heart failure hospitalization [HFH], or death) were obtained between January 2007 and June 2019 from the deidentified Optum de-identified Electronic Health Record dataset. A total of 25,752 patients (age 69.3 ± 13.9 years; 58% male) were evaluated. The average intrinsic PR interval was 185 ± 55 ms. In the subset of 16,730 patients with available long-term device diagnostic data, a total of 2555 (15.3%) individuals developed AF during 2.59 ± 2.18 years of follow-up. The incidence of AF was significantly higher (up to 30%) in patients with a longer PR interval (ie, PR interval ≥270 ms; P < .05). Time-to-event survival analysis and multivariable analysis showed that PR interval ≥190 ms was significantly associated with higher incidence of AF, HFH, or HFH or death when compared with shorter PR intervals (P < .05 for all 3 parameters). In a large real-world population of patients with implanted devices, PR interval prolongation was significantly associated with increased incidence of AF, HFH, or death.

Topics & Concepts

MedicineIncidence (geometry)Atrial fibrillationCardiologyImplantable cardioverter-defibrillatorConfidence intervalInternal medicineHeart failurePopulationSudden cardiac deathEnvironmental healthOpticsPhysicsCardiac pacing and defibrillation studiesAtrial Fibrillation Management and OutcomesHeart rate and cardiovascular health
Prolonged PR interval and incidence of atrial fibrillation, heart failure admissions, and mortality in patients with implanted cardiac devices: A real-world survey | Litcius