Litcius/Paper detail

High-resolution image-guided WEB aneurysm embolization by high-frequency optical coherence tomography

Zeynep Vardar, R King, Afif Kraitem, Erin Langan, Lindsy M. Peterson, Benjamin H Duncan, Christopher M. Raskett, Vania Anagnostakou, Matthew J. Gounis, Ajit S Puri, Giovanni J. Ughi

2020Journal of NeuroInterventional Surgery17 citationsDOIOpen Access PDF

Abstract

BACKGROUND: High-frequency optical coherence tomography (HF-OCT) is an intra-vascular imaging technique capable of assessing device-vessel interactions at spatial resolution approaching 10 µm. We tested the hypothesis that adequately deployed Woven EndoBridge (WEB) devices as visualized by HF-OCT lead to higher aneurysm occlusion rates. METHODS: In a leporine model, elastase-induced aneurysms (n=24) were treated with the WEB device. HF-OCT and digital subtraction angiography (DSA) were performed following WEB deployment and repeated at 4, 8, and 12 weeks. Protrusion (0-present, 1-absent) and malapposition (0-malapposed, 1-neck apposition >50%) were binary coded. A device was considered 'adequately deployed' by HF-OCT and DSA if apposed and non-protruding. Aneurysm healing on DSA was reported using the 4-point WEB occlusion score: A or B grades were considered positive outcome. Neointimal coverage was quantified on HF-OCT images at 12 weeks and compared with scanning electron microscopy (SEM). RESULTS: Adequate deployment on HF-OCT correlated with positive outcome (P=0.007), but no statistically significant relationship was found between good outcome and adequate deployment on DSA (P=0.289). Absence of protrusion on HF-OCT correlated with a positive outcome (P=0.006); however, malapposition alone had no significant relationship (P=0.19). HF-OCT showed a strong correlation with SEM for the assessment of areas of neointimal tissue (R²=0.96; P<0.001). More neointimal coverage of 78%±32% was found on 'adequate deployment' cases versus 31%±24% for the 'inadequate deployment' cases (P=0.001). CONCLUSION: HF-OCT visualizes features that can determine adequate device deployment to prognosticate early aneurysm occlusion following WEB implantation and can be used to longitudinally monitor aneurysm healing progression.

Topics & Concepts

MedicineDigital subtraction angiographyAneurysmOptical coherence tomographyOcclusionRadiologyEmbolizationAppositionNuclear medicineAngiographyInternal medicineCoronary Interventions and DiagnosticsIntracranial Aneurysms: Treatment and ComplicationsAortic aneurysm repair treatments