Litcius/Paper detail

Influence of Socket-shield technique on the biomechanical response of dental implant: three-dimensional finite element analysis

João Paulo Mendes Tribst, Amanda Maria de Oliveira Dal Piva, Alexandre Luiz Souto Borges, Marco Antônıo Bottıno

2020Computer Methods in Biomechanics & Biomedical Engineering14 citationsDOIOpen Access PDF

Abstract

This study evaluated the bone microstrain, displacement, and stress distribution according to the surgical technique (conventional or Socket-shield) and evaluation period (immediately after implant installation or after healing). Each condition was modeled for the finite element analysis, totaling four groups, with a morse-taper implant and a cemented prosthesis. The maximum displacement, von Mises stress, and bone microstrain yielded higher values during the immediate stage, without a difference between Socket-shield and conventional treatments. The use of the Socket-shield technique does not negatively impact the biomechanical behavior of an implant-supported prosthesis immediately after healing from the implant installation.

Topics & Concepts

von Mises yield criterionFinite element methodMaterials scienceImplantDisplacement (psychology)ShieldProsthesisDentistryOrthodonticsStress (linguistics)BiomechanicsBiomedical engineeringDental implantStructural engineeringMedicineSurgeryEngineeringGeologyAnatomyLinguisticsPhilosophyPsychotherapistPsychologyPetrologyDental Implant Techniques and OutcomesOrthopaedic implants and arthroplastyDental materials and restorations