Litcius/Paper detail

Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise

Juan Corral‐Pérez, Alberto Marín-Galindo, Manuel Costilla, Cristina Casals, Alejandro Muñoz‐López, Alberto Sánchez‐Sixto, Borja Sañudo, Jesús Gustavo Ponce‐González

2024Journal of science and medicine in sport7 citationsDOIOpen Access PDF

Abstract

Monitoring of changes in skeletal muscle oxygenation during exercise has increased in recent years. Tissue oxygenation, which is related to fatigue and muscle hypertrophy, is often measured using near-infrared spectroscopy (NIRS). Objectives This study aimed to determine the test-retest reliability of a non-portable NIRS (NIRO200Nx) during the full-squat exercise and recovery in young healthy men. Design Twenty-five male participants (21.8 ± 2.6 years) were recruited for this original research. Each participant completed an 8-repetition test with a load that elicited a velocity of 1 m·s −1 . The test was conducted twice, with a 48-hour washout period between sessions. Methods The NIRS measured the changes of oxygenated-Hemoglobin (O 2 Hb), deoxygenated-Hemoglobin (HHb) and Tissue Oxygenation Index (TOI) in both Vastus Lateralis and Vastus Medialis during rest, exercise, and recovery. Coefficient of Variation (CV), Standard Error Measurement (SEM) and Intraclass Correlation Coefficient (ICC) were used to evaluate the reliability of the data. Significance was set at p < 0.05. Results The results indicated that TOI had good to acceptable absolute reliability (CV TOI = 2.7–10.2 %). A good relative relativity for the overall test was found for Vastus Medialis O 2 Hb (ICC = 0.851), HHb (ICC = 0.852), and TOI (ICC = 0.864), and Vastus Lateralis O 2 Hb (ICC = 0.898), HHb (ICC = 0.899), and TOI (ICC = 0.897). Conclusions We conclude that NIRO200Nx is a reliable instrument for measuring muscle oxygen saturation through the TOI parameter in not-to-failure dynamic resistance exercises (1 set of 8 reps against ∼40 % 1 repetition maximum). Tissue oxygenation assessment could be a new way of individualizing exercise through dynamic resistance exercises.

Topics & Concepts

SquatReliability (semiconductor)Physical medicine and rehabilitationPhysical therapyMedicinePhysicsPower (physics)Quantum mechanicsCardiovascular and exercise physiologySports Performance and TrainingOptical Imaging and Spectroscopy Techniques
Reliability of near-infrared spectroscopy in measuring muscle oxygenation during squat exercise | Litcius