Multicomponent gas detection technology of FDM and TDM based on photoacoustic spectroscopy
Yuanfang Yu, Cunwei Tian, Zongliang Wang, Siyu Qian, Cunying Yan, Hao Zhang
Abstract
In this paper, a multicomponent gas detection system based on photoacoustic spectroscopy (PAS) is proposed with a combination of frequency division multiplexing (FDM) and time division multiplexing (TDM), combining a resonance photoacoustic cell and broadband microphone. A PAS gas cell with a wide frequency response bandwidth was used to achieve the FDM by selecting a specific modulation frequency of each component gas. The sawtooth wave driver current of each laser was output at a constant time interval for achieving the TDM. Compared with the laser channel control using a photoswitch, the driver current control was a simpler and more convenient means to implement TDM. The four gas components of methane ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>4</mml:mn> </mml:msub> </mml:mrow> </mml:math> ), water ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">O</mml:mi> </mml:mrow> </mml:math> ) vapor, carbon dioxide ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> <mml:mi mathvariant="normal">O</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> </mml:math> ), and acetylene ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> </mml:math> ) were selected as sample gases for testing the feasibility of the method. The experimental results showed that the gas detection limits of <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>4</mml:mn> </mml:msub> </mml:mrow> </mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">O</mml:mi> </mml:mrow> </mml:math> vapor, <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> <mml:mi mathvariant="normal">O</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> </mml:math> , and <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" display="inline"> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">C</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:msub> <mml:mrow class="MJX-TeXAtom-ORD"> <mml:mi mathvariant="normal">H</mml:mi> </mml:mrow> <mml:mn>2</mml:mn> </mml:msub> </mml:mrow> </mml:math> were 75.435, 2.502, 341.960, and 4.284 ppm, respectively. In addition, the linear fittings of gas concentration were 0.99386, 0.99772, 0.98995, and 0.98955, respectively.