Litcius/Paper detail

Evaluation of Commercial Anti-SARS-CoV-2 Antibody Assays and Comparison of Standardized Titers in Vaccinated Health Care Workers

Kahina Saker, Vanessa Escuret, Virginie Pitiot, Amélie Massardier-Pilonchéry, Stéphane Paul, Bouchra Mokdad, Carole Langlois-Jacques, Muriel Rabilloud, David Goncalves, Nicole Fabien, Nicolas Guibert, Jean-Baptiste Fassier, Antonin Bal, Sophie Trouillet-Assant, Mary-Anne Trabaud

2021Journal of Clinical Microbiology41 citationsDOIOpen Access PDF

Abstract

With the availability of vaccines, commercial assays detecting anti-severe acute respiratory syndrome coronavirus-2 antibodies (Ab) evolved toward quantitative assays directed to the spike glycoprotein or its receptor binding domain (RBD). The main objective of the present study was to compare the Ab titers obtained with quantitative commercial binding Ab assays, after one dose (convalescent individuals) or two doses (naive individuals) of vaccine, in health care workers (HCW). Antibody titers were measured in 255 sera (from 150 HCW) with five quantitative immunoassays (Abbott RBD IgG II quant, bioMérieux RBD IgG, DiaSorin Trimeric spike IgG, Siemens Healthineers RBD IgG, Wantai RBD IgG). One qualitative total antibody anti-RBD detection assay (Wantai) was used to detect previous infection before vaccination. The results are presented in binding Ab units (BAU)/mL after application, when possible, of a conversion factor provided by the manufacturers and established from a World Health Organization internal standard. There was a 100% seroconversion with all assays evaluated after two doses of vaccine. With assays allowing BAU/mL correction, Ab titers were correlated (Pearson correlation coefficient, ρ, range: 0.85-0.94). The titer differences varied by a mean of 10.6% between Siemens and bioMérieux assays to 60.9% between Abbott and DiaSorin assays. These results underline the importance of BAU conversion for the comparison of Ab titer obtained with the different quantitative assays. However, significant differences persist, notably, between kits detecting Ab against the different antigens. A true standardization of the assays would be to include the International Standard in the calibration of each assay to express the results in IU/mL.

Topics & Concepts

SeroconversionTiterMedicineAntibodyAntibody titerImmunoassayImmunologyVirologySerologyInternal medicineMulticenter studySevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2)Quantitative analysis (chemistry)SARS-CoV-2 and COVID-19 ResearchSARS-CoV-2 detection and testingCOVID-19 Clinical Research Studies