Litcius/Paper detail

A D-Shaped SPR-Based PCF Sensor with an Extremely High-Amplitude Sensitivity for Measuring the Refractive Index

W. Li, Yu Chen, Jianjie Xu, Menglin Jiang, Hui Zou

2023Micromachines28 citationsDOIOpen Access PDF

Abstract

In this work, a new D-shaped photonic crystal fibre sensor structure based on surface plasmon resonance (SPR) is purposed for measurement of analyte refractive index (RI). In this design, a silica cylinder is polished into a D-shaped silica material structure with a flattened surface where two Au nanowires are coated. Some air holes are omitted to form the core mode region. With the implementation of gold nanowires and a core region for the exciting SPR effect with variate physical values, analyte RI can be measured with a wavelength coverage from 850 to 1350nm. The numerical simulation shows the maximum wavelength sensitivity of the purposed design achieves 19,600nm/RIU with an RI coverage from 1.37 to 1.42. Moreover, the sensor has a tremendous amplitude sensitivity and the maximum absolute value is about 2300RIU-1. Benefiting from these outstanding performance, the purposed structure can be given priority when it is applied in biomedical detecting and environmental assessment science.

Topics & Concepts

Refractive indexMaterials scienceAnalyteSurface plasmon resonanceWavelengthSensitivity (control systems)NanowireOpticsPhotonic-crystal fiberDispersion (optics)Core (optical fiber)OptoelectronicsNanotechnologyNanoparticleElectronic engineeringChemistryComposite materialPhysicsEngineeringPhysical chemistryAdvanced Fiber Optic SensorsPhotonic and Optical DevicesPlasmonic and Surface Plasmon Research