Litcius/Paper detail

Reduced Graphene/Polydopamine-Supported Au@Pt/Au Nanoparticles for Electrochemical Detection of Acetaminophen

Ling Shi, Zefeng Wang, Na Wu, Xianlan Chen, Guangming Yang, Wei Liu

2020International Journal of Electrochemical Science19 citationsDOIOpen Access PDF

Abstract

In this work, we report an efficient electrochemical sensor made from reduced graphene/polydopamine supported Au@Pt/Au (GN/PDA/Au@Pt/Au) nanoparticles for detection of acetaminophen (ACOP). The electrochemical reaction mechanism is investigated using cyclic voltammetry (CV). The Electrocatalytic activity is monitored under varying pH. The ACOP is detected under the optimal condition. A linear range from 1 to 300 μM is achieved with a limit of detection of 0.31 μM. The fabricated sensor show satisfactory results in commercial tablets.

Topics & Concepts

GrapheneAcetaminophenElectrochemistryMaterials scienceNanoparticleNanotechnologyNuclear chemistryChemistryElectrodePhysical chemistryBiochemistryElectrochemical sensors and biosensorsAdvanced Nanomaterials in CatalysisAdvanced biosensing and bioanalysis techniques
Reduced Graphene/Polydopamine-Supported Au@Pt/Au Nanoparticles for Electrochemical Detection of Acetaminophen | Litcius