Litcius/Paper detail

Re‐CHARGE‐AF: Recalibration of the CHARGE‐AF Model for Atrial Fibrillation Risk Prediction in Patients With Acute Stroke

Jeffrey M. Ashburner, Xin Wang, Xinye Li, Shaan Khurshid, Darae Ko, Ana Trisini Lipsanopoulos, Priscilla R. Lee, Taylor Carmichael, Ashby C. Turner, Corban Jackson, Patrick T. Ellinor, Emelia J. Benjamin, Steven J. Atlas, Daniel E. Singer, Ludovic Trinquart, Steven A. Lubitz, Christopher D. Anderson

2021Journal of the American Heart Association18 citationsDOIOpen Access PDF

Abstract

Background Performance of existing atrial fibrillation (AF) risk prediction models in poststroke populations is unclear. We evaluated predictive utility of an AF risk model in patients with acute stroke and assessed performance of a fully refitted model. Methods and Results Within an academic hospital, we included patients aged 46 to 94 years discharged for acute ischemic stroke between 2003 and 2018. We estimated 5‐year predicted probabilities of AF using the Cohorts for Heart and Aging Research in Genomic Epidemiology for Atrial Fibrillation (CHARGE‐AF) model, by recalibrating CHARGE‐AF to the baseline risk of the sample, and by fully refitting a Cox proportional hazards model to the stroke sample (Re‐CHARGE‐AF) model. We compared discrimination and calibration between models and used 200 bootstrap samples for optimism‐adjusted measures. Among 551 patients with acute stroke, there were 70 incident AF events over 5 years (cumulative incidence, 15.2%; 95% CI, 10.6%–19.5%). Median predicted 5‐year risk from CHARGE‐AF was 4.8% (quartile 1–quartile 3, 2.0–12.6) and from Re‐CHARGE‐AF was 16.1% (quartile 1–quartile 3, 8.0–26.2). For CHARGE‐AF, discrimination was moderate (C statistic, 0.64; 95% CI, 0.57–0.70) and calibration was poor, underestimating AF risk (Greenwood‐Nam D’Agostino chi‐square, P <0.001). Calibration with recalibrated baseline risk was also poor (Greenwood‐Nam D’Agostino chi‐square, P <0.001). Re‐CHARGE‐AF improved discrimination ( P =0.001) compared with CHARGE‐AF (C statistic, 0.74 [95% CI, 0.68–0.79]; optimism‐adjusted, 0.70 [95% CI, 0.65–0.75]) and was well calibrated (Greenwood‐Nam D’Agostino chi‐square, P =0.97). Conclusions Covariates from an established AF risk model enable accurate estimation of AF risk in a poststroke population after recalibration. A fully refitted model was required to account for varying baseline AF hazard and strength of associations between covariates and incident AF.

Topics & Concepts

MedicineAtrial fibrillationStroke (engine)Internal medicineCardiologyProportional hazards modelEpidemiologyPopulationAcute strokeRisk assessmentCovariateStroke riskCalibrationBaseline (sea)Predictive value of testsHeart failureRisk factorEmbolic strokeFramingham Risk ScorePredictive modellingProspective cohort studyEmergency medicineIschemic strokeSample size determinationPopulation studyLower riskAtrial Fibrillation Management and OutcomesAcute Ischemic Stroke ManagementHeart Failure Treatment and Management