Litcius/Paper detail

DIABETIC MACULAR EDEMA AND CATARACT SURGERY

Claudio Furino, Francesco Boscia, Alfredo Niro, Maria D’Addario, Maria Oliva Grassi, Valeria Saglimbene, Michele Reibaldi, Giovanni Alessio

2020Retina25 citationsDOIOpen Access PDF

Abstract

PURPOSE: To compare functional and anatomical results of combined phacoemulsification and dexamethasone intravitreal implant (Ozurdex; DEX-I) with standard phacoemulsification in diabetic patients with cataract. METHODS: Retrospective, comparative, cohort study. Patients with nonproliferative diabetic retinopathy, macular edema, and cataract, treated routinely at the Eye Clinic, Azienda Ospedaliero Universitaria Policlinico, Bari, Italy with phacoemulsification associated with DEX-I (n = 23; Phaco-Dex) or standard phacoemulsification (n = 23; Phaco-alone). Best-correct visual acuity, central subfield thickness, and intraocular pressure were assessed at baseline and monthly for 3 months after surgery, and t-test was used to assess change from baseline. A multilevel regression model with an unstructured correlation-type matrix to account for repeated data measures was used for statistical analysis in and between groups. RESULTS: With Phaco-Dex, best-correct visual acuity increased significantly from the first month (P = 0.0005 vs. baseline) and remained stable at the following visits; central subfield thickness decreased significantly from Month 2 (P = 0.049 and P = 0.04 vs. baseline, respectively); at each timepoint, central subfield thickness was significantly lower in the Phaco-Dex group versus Phaco-alone. Intraocular pressure increased significantly during follow-up (P = 0.001 at Month 3 vs. baseline) but remained within the normal range. In the Phaco-alone group, best-correct visual acuity, and intraocular pressure did not show any significant changes after surgery, whereas central subfield thickness increased from Month 2 (P = 0.05 vs. baseline). CONCLUSION: In diabetic patients with macular edema and visually significant cataract, combined treatment with phacoemulsification and DEX-I seemed to be effective, safe, and superior to standard phacoemulsification considering both functional and tomographic parameters.

Topics & Concepts

MedicinePhacoemulsificationOphthalmologyVisual acuityIntraocular pressureDiabetic retinopathyMacular edemaCataract surgeryIntraocular lensDexamethasoneDiabetes mellitusInternal medicineEndocrinologyRetinal Diseases and TreatmentsGlaucoma and retinal disordersRetinal and Macular Surgery