Litcius/Paper detail

Postoperative clinical outcomes for kinematically, restricted kinematically, or mechanically aligned total knee arthroplasty: a systematic review and network meta-analysis of randomized controlled trials

Takanori Miura, Tsuneari Takahashi, Jun Watanabe, Yuki Kataoka, Ryusuke Ae, Hidetomo Saito, Katsushi Takeshita, Naohisa Miyakoshi

2023BMC Musculoskeletal Disorders23 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Mechanically aligned total knee arthroplasty (MATKA) is a well-established procedure. Kinematically aligned TKA (KATKA) has been proposed to restore and preserve pre-arthritic knee anatomy. However, normal knee anatomy varies widely, and there have been concerns regarding restoring unusual anatomy. Accordingly, restricted KATKA (rKATKA) was introduced to reproduce constitutional knee anatomy within a safe range. This network meta-analysis (NMA) aimed to evaluate the clinical and radiological outcomes of the surgeries. METHODS: We performed a database search on August 20, 2022, which included randomized controlled trials (RCTs) comparing any two of the three surgical TKA techniques for knee osteoarthritis. We conducted a random-effects NMA within the frequentist framework and evaluated confidence in each outcome using the Confidence in Network Meta-Analysis tool. RESULTS: Ten RCTs with 1,008 knees and a median follow-up period of 1.5 years were included. The three methods might result in little to no difference in range of motion (ROM) between methods. In patient-reported outcome measures (PROMs), the KATKA might result in a slight improvement compared with the MATKA (standardized mean difference, 0.47; 95% confidence interval [CI], 0.16-0.78; very low confidence). There was little to no difference in revision risk between MATKA and KATKA. KATKA and rKATKA showed a slight valgus femoral component (mean difference [MD], -1.35; 95% CI, -1.95-[-0.75]; very low confidence; and MD, -1.72; 95% CI, -2.63-[-0.81]; very low confidence, respectively) and a slight varus tibial component (MD, 2.23; 95% CI, 1.22-3.24; very low confidence; and MD, 1.25; 95% CI, 0.01-2.49; very low confidence, respectively) compared with MATKA. Tibial component inclination and hip-knee-ankle angle might result in little to no difference between the three procedures. CONCLUSIONS: KATKA and rKATKA showed similar ROM and PROMs and a slight variation in the coronal component alignment compared with MATKA. KATKA and rKATKA are acceptable methods in short- to mid-term follow-up periods. However, long-term clinical results in patients with severe varus deformity are still lacking. Surgeons should choose surgical procedures carefully. Further trials are warranted to evaluate the efficacy, safety, and subsequent revision risk.

Topics & Concepts

MedicineConfidence intervalSports medicineMeta-analysisRandomized controlled trialFrequentist inferenceOsteoarthritisRange of motionValgusTotal knee arthroplastyArthroplastyOrthopedic surgeryOdds ratioPhysical therapySurgeryInternal medicineBayesian inferenceBayesian probabilityComputer scienceArtificial intelligenceAlternative medicinePathologyTotal Knee Arthroplasty OutcomesOrthopaedic implants and arthroplastyOrthopedic Infections and Treatments