Litcius/Paper detail

Comparing the diagnostic accuracy of 4D CT and 99mTc-MIBI SPECT/CT for localizing hyperfunctioning parathyroid glands: a systematic review and meta-analysis

Qi-chang Wan, Jianfang Li, Lei-lei Tang, Jie Lv, Liangjun Xie, Jinping Li, Luping Qin, Mu‐hua Cheng

2020Nuclear Medicine Communications26 citationsDOI

Abstract

PURPOSE: To compare the diagnostic accuracy of dual-phase 99mTc-MIBI single photon emission computed tomography/computed tomography (SPECT/CT) and 4D CT for the localization of hyperfunctioning parathyroid glands, a systematic review and meta-analysis was performed. Whether 4D CT combined to SPECT/CT [contrast-enhanced (CE)-SPECT/CT] had a better diagnostic performance than SPECT/CT alone in this scenario was also evaluated. MATERIAL AND METHODS: PubMed and Embase databases were searched for eligible studies. To reduce interstudy heterogeneity, only studies with clear head-to-head comparison were included. Publication bias was assessed by the Deeks funnel plot. The pooled sensitivity, specificity and the area under the curve (AUC) for 4D CT, SPECT/CT and CE-SPECT/CT were determined by random-effect analysis, respectively. RESULTS: Nine studies met the inclusion criteria, with a total of 911 participants. The sensitivity and specificity of 4D CT were 0.85 [95% confidence interval (CI), 0.69-0.94] and 0.93 (95% CI, 0.88-0.96), whereas the sensitivity and specificity for SPECT/CT were 0.68 (95% CI, 0.51-0.82; P = 0.048 compared with 4D CT) and 0.98 (95% CI, 0.95-0.99; P = 0.014 compared with 4D CT), respectively. CE-SPECT/CT is comparable to SPECT/CT in specificity and AUC, but it may improve the sensitivity (although there was a lack of statistical difference, 0.87 vs. 0.78; P = 0.125). CONCLUSION: Although 4D CT shows comparable AUC and borderline better sensitivity than SPECT/CT, its clinical application is confined by relatively low specificity and high radiation exposure. CE-SPECT/CT may improve the sensitivity without compromising the specificity and AUC of SPECT/CT.

Topics & Concepts

MedicineNuclear medicineConfidence intervalMeta-analysisSingle-photon emission computed tomographyReceiver operating characteristicDiagnostic accuracyEmission computed tomographyRadiologyPositron emission tomographyInternal medicineParathyroid Disorders and TreatmentsThyroid and Parathyroid SurgeryMedical Imaging and Pathology Studies
Comparing the diagnostic accuracy of 4D CT and 99mTc-MIBI SPECT/CT for localizing hyperfunctioning parathyroid glands: a systematic review and meta-analysis | Litcius