Litcius/Paper detail

Contraceptive efficacy and safety of the 52-mg levonorgestrel intrauterine system for up to 8 years: findings from the Mirena Extension Trial

Jeffrey T. Jensen, Eeva Lukkari‐Lax, Andrea Schulze, Yesmean Wahdan, Marco Serrani, Robin Kroll

2022American Journal of Obstetrics and Gynecology48 citationsDOIOpen Access PDF

Abstract

BackgroundThe 52-mg levonorgestrel-releasing intrauterine system is an established, long-acting contraceptive option with approved use for up to 7 years.ObjectiveThe Mirena Extension Trial evaluated the efficacy and safety of the 52-mg levonorgestrel-releasing intrauterine system during extended use beyond 5 and up to 8 years.Study DesignThis was a multicenter, single-arm study in the United States, enrolling existing users of the 52-mg levonorgestrel-releasing intrauterine system, aged 18 to 35 years, who have had the system for 4.5 to 5 years. We assessed the contraceptive efficacy (Pearl Index) and cumulative failure rate (using the Kaplan–Meier method) of the 52-mg levonorgestrel-releasing intrauterine system during extended use. We also evaluated bleeding outcomes and adverse events.ResultsOf the 362 participants starting year 6, 243 entered and 223 completed 8 years of 52-mg levonorgestrel-releasing intrauterine system use. Just more than half the participants were parous. The mean (standard deviation) age was 29.2 (±2.9) years, and all participants were aged ≤36 years at the end of year 8. Two pregnancies occurred, both with the device in situ. The year 6 pregnancy was of undetermined location and resolved spontaneously. The pregnancy in year 7 was ectopic and resolved with methotrexate treatment. In both cases, the 52-mg levonorgestrel-releasing intrauterine system was removed and the participants left the trial. For years 6 to 8, the 3-year Pearl Index (95% confidence interval) was 0.28 (0.03–1.00) with a 3-year cumulative failure rate of 0.68% (0.17–2.71). Pearl Indexes for years 6, 7, and 8 were 0.34 (0.01–1.88), 0.40 (0.01–2.25), and 0.00 (0.00–1.90), respectively. The 3-year (years 6–8) ectopic pregnancy Pearl Index was 0.14 (0.00–0.77). We found treatment-emergent adverse events in 249 of 362 participants (68.8%), with 65 (18.0%) events considered to be related to the 52-mg levonorgestrel-releasing intrauterine system. The discontinuation rate was 38.4% (139/362), most commonly because of desire for pregnancy (12.2%, 44/362). During extended use beyond 5 years and up to 8 years, participants reported a decrease in the mean number of bleeding or spotting days with approximately half of the women experiencing amenorrhea or infrequent bleeding. We did not enroll a sufficient number of women using the 52-mg levonorgestrel-releasing intrauterine system for contraception and heavy menstrual bleeding to assess extended use for that indication. At the end of year 8, most (98.7%, 220/223) of the participants who completed the study remained satisfied with the continued use of the 52-mg levonorgestrel-releasing intrauterine system. Of the 31 women who discontinued early because of desire for pregnancy with evaluable data for return-to-fertility analysis, 24 reported a posttreatment pregnancy within 1 year, giving a 12-month return-to-fertility rate of 77.4%.ConclusionThe 52-mg levonorgestrel-releasing intrauterine system, initially approved for 5 years, maintains high contraceptive efficacy, user satisfaction, and a favorable safety profile through 8 years of use. Participants reported 26 posttreatment pregnancies in total, of which 24 occurred in women who had discontinued the 52-mg levonorgestrel-releasing intrauterine system because of a desire for pregnancy. Of note, among women who elected to continue use through 8 years, bleeding patterns remained highly favorable. These findings support continued 52-mg levonorgestrel-releasing intrauterine system use for up to 8 years in women who wish to continue treatment. The 52-mg levonorgestrel-releasing intrauterine system is an established, long-acting contraceptive option with approved use for up to 7 years. The Mirena Extension Trial evaluated the efficacy and safety of the 52-mg levonorgestrel-releasing intrauterine system during extended use beyond 5 and up to 8 years. This was a multicenter, single-arm study in the United States, enrolling existing users of the 52-mg levonorgestrel-releasing intrauterine system, aged 18 to 35 years, who have had the system for 4.5 to 5 years. We assessed the contraceptive efficacy (Pearl Index) and cumulative failure rate (using the Kaplan–Meier method) of the 52-mg levonorgestrel-releasing intrauterine system during extended use. We also evaluated bleeding outcomes and adverse events. Of the 362 participants starting year 6, 243 entered and 223 completed 8 years of 52-mg levonorgestrel-releasing intrauterine system use. Just more than half the participants were parous. The mean (standard deviation) age was 29.2 (±2.9) years, and all participants were aged ≤36 years at the end of year 8. Two pregnancies occurred, both with the device in situ. The year 6 pregnancy was of undetermined location and resolved spontaneously. The pregnancy in year 7 was ectopic and resolved with methotrexate treatment. In both cases, the 52-mg levonorgestrel-releasing intrauterine system was removed and the participants left the trial. For years 6 to 8, the 3-year Pearl Index (95% confidence interval) was 0.28 (0.03–1.00) with a 3-year cumulative failure rate of 0.68% (0.17–2.71). Pearl Indexes for years 6, 7, and 8 were 0.34 (0.01–1.88), 0.40 (0.01–2.25), and 0.00 (0.00–1.90), respectively. The 3-year (years 6–8) ectopic pregnancy Pearl Index was 0.14 (0.00–0.77). We found treatment-emergent adverse events in 249 of 362 participants (68.8%), with 65 (18.0%) events considered to be related to the 52-mg levonorgestrel-releasing intrauterine system. The discontinuation rate was 38.4% (139/362), most commonly because of desire for pregnancy (12.2%, 44/362). During extended use beyond 5 years and up to 8 years, participants reported a decrease in the mean number of bleeding or spotting days with approximately half of the women experiencing amenorrhea or infrequent bleeding. We did not enroll a sufficient number of women using the 52-mg levonorgestrel-releasing intrauterine system for contraception and heavy menstrual bleeding to assess extended use for that indication. At the end of year 8, most (98.7%, 220/223) of the participants who completed the study remained satisfied with the continued use of the 52-mg levonorgestrel-releasing intrauterine system. Of the 31 women who discontinued early because of desire for pregnancy with evaluable data for return-to-fertility analysis, 24 reported a posttreatment pregnancy within 1 year, giving a 12-month return-to-fertility rate of 77.4%. The 52-mg levonorgestrel-releasing intrauterine system, initially approved for 5 years, maintains high contraceptive efficacy, user satisfaction, and a favorable safety profile through 8 years of use. Participants reported 26 posttreatment pregnancies in total, of which 24 occurred in women who had discontinued the 52-mg levonorgestrel-releasing intrauterine system because of a desire for pregnancy. Of note, among women who elected to continue use through 8 years, bleeding patterns remained highly favorable. These findings support continued 52-mg levonorgestrel-releasing intrauterine system use for up to 8 years in women who wish to continue treatment.

Topics & Concepts

LevonorgestrelMedicineObstetricsFamily planningGynecologyPopulationResearch methodologyEnvironmental healthReproductive Health and ContraceptionOvarian function and disordersReproductive Health and Technologies