Modeling the Moiré fringe visibility of Talbot-Lau X-ray grating interferometry for single-frame multi-contrast imaging

Kai Deng, Jing Li, Weiping Xie

2020Optics Express14 citationsDOIOpen Access PDF

Abstract

Moiré fringe method in X-ray grating interferometry is characterized by its advantage to obtain multi-contrast data through single-frame imaging. However, how the visibility of the Moiré fringe is influenced by the system parameters, such as the misalignment angle, still lacks investigation, although it closely relates to the signal-to-noise ratio of the image data. In this paper, a simplified model of the Moiré fringe visibility is presented, which reveals that the Moiré fringe visibility can be expressed as the product of a misalignment-angle-related "sinc" function and a relatively independent factor. The following experimental results further suggest that the crosstalk between the detector pixels in the direction perpendicular to the Moiré fringe orientation is another main cause for the visibility reduction of the Moiré fringes.

Topics & Concepts

OpticsMoiré patternVisibilityInterferometryGratingPhysicsSpeckle patternSpatial frequencyDetectorAdvanced X-ray Imaging TechniquesOptical measurement and interference techniquesAdvancements in Photolithography Techniques