Litcius/Paper detail

Skeletal muscle fat quantification by dual-energy computed tomography in comparison with 3T MR imaging

Isabel Molwitz, Miriam Leiderer, Rosalie McDonough, Roland Fischer, AK Ozga, Cüneyt Özden, Enver Tahir, Daniel Koehler, Gerhard Adam, Jin Yamamura

2021European Radiology42 citationsDOIOpen Access PDF

Abstract

OBJECTIVES: To quantify the proportion of fat within the skeletal muscle as a measure of muscle quality using dual-energy CT (DECT) and to validate this methodology with MRI. METHODS: ) within the posterior paraspinal muscle. For validation, the MR-based fat fraction (MR-FF) was assessed by chemical shift relaxometry. Patients were categorized into groups of high or low skeletal muscle mean radiation attenuation (SMRA) and classified as either sarcopenic or non-sarcopenic, according to the skeletal muscle index (SMI) and cut-off values from non-contrast-enhanced single-energy CT. Spearman's and intraclass correlation, Bland-Altman analysis, and mixed linear models were employed. RESULTS: The correlation was excellent between DECT-FF and MR-FF (r = 0.91), DECT VNC HU and MR-FF (r = - 0.90), and DECT-FF and DECT VNC HU (r = - 0.98). Intraclass correlation between DECT-FF and MR-FF was good (r = 0.83 [95% CI 0.71-0.90]), with a mean difference of - 0.15% (SD 3.32 [95% CI 6.35 to - 6.66]). Categorization using the SMRA yielded an eightfold difference in DECT VNC HU values between both groups (5 HU [95% CI 23-11], 42 HU [95% CI 33-56], p = 0.05). No significant relationship between DECT-FF and SMI-based classifications was observed. CONCLUSIONS: Fat quantification within the skeletal muscle using DECT is both feasible and reliable. DECT muscle analysis offers a new approach to determine muscle quality, which is important for the diagnosis and therapeutic monitoring of sarcopenia, as a comorbidity associated with poor clinical outcome. KEY POINTS: • Dual-energy CT (DECT) material decomposition and virtual non-contrast-enhanced DECT HU values assess muscle fat reliably. • Virtual non-contrast-enhanced dual-energy CT HU values allow to differentiate between high and low native skeletal muscle mean radiation attenuation in contrast-enhanced DECT scans. • Measuring muscle fat by dual-energy computed tomography is a new approach for the determination of muscle quality, an important parameter for the diagnostic confirmation of sarcopenia as a comorbidity associated with poor clinical outcome.

Topics & Concepts

MedicineIntraclass correlationNuclear medicineNeuroradiologyRadiologyNeurologyPsychometricsClinical psychologyPsychiatryNutrition and Health in AgingBody Composition Measurement TechniquesFrailty in Older Adults
Skeletal muscle fat quantification by dual-energy computed tomography in comparison with 3T MR imaging | Litcius