Litcius/Paper detail

Development of a Flexible Smart Wearable Oximeter Insole for Monitoring SpO<sub>2</sub> Levels of Diabetics’ Foot Ulcer

Masoud Shariat Panahi, S. Masihi, Anthony J. Hanson, Jose Ignacio Rodriguez-Labra, Ahmad Masihi, Dinesh Maddipatla, Binu B. Narakathu, Daryl Lawson, Massood Z. Atashbar

2022IEEE Journal on Flexible Electronics17 citationsDOI

Abstract

This work presents the development of a fully functional prototype of a wearable smart shoe insole that can monitor arterial oxygen saturation (SpO <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> ) levels at the foot of a diabetic patient using photoplethysmography (PPG) signals. Continuous monitoring of SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> levels at foot in patients with diabetic foot ulcer (DFU) can provide critical information on the severity of the ulcer, the wound healing process, and alerting clinicians for critical limb ischemia. The developed oximetry system seamlessly integrates the Internet of Things (IoT) via a custom-developed Android mobile application, thus enabling “at-home” monitoring. Twenty healthy subjects were tested, and the insole oximeter could successfully estimate SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> levels at the toe. An average error of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\approx 2.6$ </tex-math></inline-formula> % was calculated for the measured/estimated SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> levels at the subjects’ toe when compared to a reference oximeter attached to the finger. Perfusion index (PI)—which represents the blood flow/supply in tissues—was used as a method for validating the oximeter readings. It was observed that fingers (index fingers) generally have larger PI values when compared to the toe, while PI results of both monitoring sites were in the acceptable range. In addition, a dataset was formed for the 20 test subjects, and machine learning (ML) techniques were applied to predict the SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> level and the site of measurement (finger or toe), using multiple linear regression and classification methods. The ML results show that alternating current (ac) components of the PPG signals have a more significant contribution to the SpO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> estimations when compared to the direct current (dc) components. In addition, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$K$ </tex-math></inline-formula> -nearest neighbor (KNN) ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$K$ </tex-math></inline-formula> = 1) classifier could successfully predict the monitoring sites, with a test accuracy of 96.86%.

Topics & Concepts

Wearable computerFoot (prosody)Physical medicine and rehabilitationMedicineComputer sciencePhysical therapyBiomedical engineeringEmbedded systemLinguisticsPhilosophyNon-Invasive Vital Sign MonitoringOptical Imaging and Spectroscopy TechniquesDiabetic Foot Ulcer Assessment and Management
Development of a Flexible Smart Wearable Oximeter Insole for Monitoring SpO<sub>2</sub> Levels of Diabetics’ Foot Ulcer | Litcius