Litcius/Paper detail

Efficient replacement of the radioactive sources in the gas-filled surge arresters construction for the insulation co-ordination at the low voltage level

Teodora Nedić, Aco Janičijević, Koviljka Stanković, Nenad Kartalović

2020Nuclear Technology and Radiation Protection12 citationsDOIOpen Access PDF

Abstract

The possibility of the classical response rate engineering and the long-term deconditioning of the gas-filled surge arresters is considered in this paper. The obtained results are compared with the same results obtained with the gas-filled surge arrester with application of an alpha radioactive source. The work is of an experimental nature. Experiments were performed on the multipurpose gas-filled surge arrester model under well-controlled conditions. The measurement uncertainty of the experimental procedure was less than 8 %. The results were processed by statistical data processing software. To draw impulse characteristics, the law of constancy of surfaces below the impulse voltage in the volt-second area, was used.

Topics & Concepts

Surge arresterImpulse (physics)VoltageSurgeOvervoltageNuclear engineeringLightning arresterEnvironmental scienceMaterials scienceElectrical engineeringEngineeringPhysicsQuantum mechanicsVacuum and Plasma ArcsRadiation Effects in ElectronicsPulsed Power Technology Applications