Litcius/Paper detail

Development and validation of determination of genotoxic impurity Bromoethane in Vigabatrin drug substance using head space gas chromatographic method [HS-GC]

Narapureddy Krishna Prasad, Devi Sravanthi Alladi

2023Pharmacia11 citationsDOIOpen Access PDF

Abstract

A specific HS-GC method has been developed, optimized, and validated for the determination of genotoxic impurity Bromoethane in Vigabatrin (VGB) drug substance. Chromatographic separation of genotoxic Bromoethane impurity was achieved on DB-1 column (30 m × 0.53 mm, 5.0 μm), consists of 100% dimethyl polysiloxane as stationary phase and passing nitrogen carrier gas. The performance of the method was assessed by evaluating the specificity, linearity, sensitivity, precision, and accuracy experiments. The established limit of detection and limit of quantification values for the genotoxic impurity was in the range of 3.57–10.80 μg/mL. The correlation coefficient value of the linearity experiment was 0.9880. The average recoveries for the accuracy were in the range of 95.3–106.8%. The results proved that the method is suitable for the determination of Bromoethane content in Vigabatrin.

Topics & Concepts

Detection limitChromatographyImpurityChemistryVigabatrinAnalytical Chemistry (journal)LinearityGas chromatographyAnticonvulsantOrganic chemistryMedicineEpilepsyQuantum mechanicsPsychiatryPhysicsAnalytical Chemistry and Chromatography