Litcius/Paper detail

Effective Cooling of Gateway Equipment Based on Atmospheric Water Adsorption–Desorption Process

Jie Zhao, Zeyang Yan, Buwei Zhu, Cheng Xue, Xue‐Ting Jin, Min Liu, SiweI Sun, Yang‐Hui Luo

2025Nano Letters12 citationsDOI

Abstract

Excessive temperatures can significantly impair the service life and performance of electronic devices, making the cooling of such devices an increasingly critical issue. This Communication introduces for the first time a three-dimensional hydrogel designed for effective thermal management. The heat from the gateway equipment is absorbed through the desorption of water molecules within the composite hygroscopic material (SHM) encapsulated in the gel, leading to a remarkable cooling effect. Additionally, the material's spontaneous adsorption capability enables self-recovery. Under conditions of 80% relative humidity and at a voltage of 5.5 V, 0.35 g of hygroscopic material (with a 5% content) has demonstrated a significant cooling effect, achieving a temperature reduction of up to 11.5 °C. This represents a substantial advancement compared to traditional phase change materials (PCM). The approach holds broad application prospects for the future.

Topics & Concepts

AdsorptionDesorptionProcess (computing)Gateway (web page)Environmental scienceMaterials scienceProcess engineeringChemical engineeringChemistryComputer scienceEngineeringPhysical chemistryWorld Wide WebOperating systemThermal properties of materialsHeat Transfer and OptimizationAdsorption and Cooling Systems