Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT

Theresa Sophie Patzer, Andreas Steven Kunz, Henner Huflage, Karsten Sebastian Luetkens, Nora Conrads, Philipp Gruschwitz, Pauline Pannenbecker, Süleyman Ergün, Thorsten Alexander Bley, Jan‐Peter Grunz

2023Scientific Reports15 citationsDOIOpen Access PDF

Abstract

Abstract Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDI vol = 5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as “non-UHR”. Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (ρ 50 = 12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2–9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p < 0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p < 0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p > 0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58–0.73; p < 0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p < 0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.

Topics & Concepts

MedicineNuclear medicineImage qualityIntraclass correlationImage noiseDetectorRadiologyOpticsPhysicsArtificial intelligenceClinical psychologyComputer sciencePsychometricsImage (mathematics)Advanced X-ray and CT ImagingRadiation Dose and ImagingDental Radiography and Imaging
Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT | Litcius