Litcius/Paper detail

Calcium scoring on coronary computed angiography tomography with photon-counting detector technology: Predictors of performance

Milán Vecsey-Nagy, Ákos Varga‐Szemes, Tilman Emrich, Emese Zsarnóczay, Norbert Nagy, Nicola Fink, Bernhard Schmidt, Tristan Nowak, Máté G. Kiss, Borbála Vattay, Melinda Boussoussou, Márton Kolossváry, A. Kubovje, Béla Merkely, Pál Maurovich‐Horvat, Bálint Szilveszter

2023Journal of cardiovascular computed tomography11 citationsDOIOpen Access PDF

Abstract

INTRODUCTION: Obtaining accurate coronary artery calcium (CAC) score measurements from CCTA datasets with virtual non-iodine (VNI) algorithms would reduce acquisition time and radiation dose. We aimed to assess the agreement of VNI-derived and conventional true non-contrast (TNC)-based CAC scores and to identify the predictors of accuracy. METHODS: CCTA datasets were acquired with either 120 or 140 ​kVp. CAC scores and volumes were calculated from TNC and VNI images in 197 consecutive patients undergoing CCTA. CAC density score, mean volume/lesion, aortic Hounsfield units and standard deviations were then measured. Finally, percentage deviation (VNI - TNC/TNC∗100) of CTA-derived CAC scores from non-enhanced scans was calculated for each patient. Predictors (including anthropometric and acquisition parameters, as well as CAC characteristics) of the degree of discrepancy were evaluated using linear regression analysis. RESULTS: While the agreement between TNC and VNI was substantial (mean bias, 6.6; limits of agreement, 178.5/145.3), a non-negligible proportion of patients (36/197, 18.3%) were falsely reclassified as CAC score ​= ​0 on VNI. The use of higher tube voltage significantly decreased the percentage deviation relative to TNC-based values (β ​= ​-0.21 [95%CI: 0.38 to -0.03], p ​= ​0.020) and a higher CAC density score also proved to be an independent predictor of a smaller difference (β ​= ​-0.22 [95%CI: 0.37 to -0.07], p ​= ​0.006). CONCLUSION: The performance of VNI-based calcium scoring may be improved by increased tube voltage protocols, while the accuracy may be compromised for calcified lesions of lower density. The implementation of VNI in clinical routine, however, needs to be preceded by a solution for detecting smaller lesions as well.

Topics & Concepts

MedicineHounsfield scaleNuclear medicineCoronary artery calciumRadiologyStandard deviationComputed tomography angiographyCoronary angiographyCardiologyAngiographyComputed tomographyStatisticsMathematicsMyocardial infarctionCardiac Imaging and DiagnosticsAdvanced X-ray and CT ImagingMedical Imaging Techniques and Applications