Litcius/Paper detail

FIDELITY: A quality control system for droplet microfluidics

Han Zhang, Can Huang, Yuwen Li, Rohit Gupte, Ryan Samuel, Jing Dai, Adrian R. Guzman, Rushant Sabnis, Paul de Figueiredo, Arum Han

2022Science Advances25 citationsDOIOpen Access PDF

Abstract

Droplet microfluidic systems have been widely deployed to interrogate biological and chemical systems. The major limitations of these systems are the relatively high error rates from critical droplet manipulation functions. To address these limitations, we describe the development of FIDELITY (Flotation and Interdigitated electrode forces on Droplets to Enable Lasting system IntegriTY), a highly sensitive and accurate size-based droplet bandpass filter that leverages the natural buoyancy of aqueous droplets and highly localized dielectrophoretic force generated by interdigitated electrode arrays. Droplet manipulation accuracies greater than 99% were achieved at a throughput of up to 100 droplets/s and separation of droplets that differed in diameter by only 6 μm was demonstrated. Last, the utility of FIDELITY was demonstrated in a droplet size quality control application and also in a droplet-based in vitro transcription/translation workflow. We anticipate FIDELITY to be integrated into a broad range of droplet microfluidic configurations to achieve exceptional operational accuracy.

Topics & Concepts

MicrofluidicsNanotechnologyMaterials scienceFidelityComputer scienceBuoyancyHigh fidelityDigital microfluidicsBiological systemOptoelectronicsMechanicsAcousticsPhysicsBiologyElectrowettingTelecommunicationsDielectricInnovative Microfluidic and Catalytic Techniques InnovationElectrowetting and Microfluidic TechnologiesMicrofluidic and Capillary Electrophoresis Applications