Litcius/Paper detail

Phantom and clinical evaluation of the effect of a new Bayesian penalized likelihood reconstruction algorithm (HYPER Iterative) on 68Ga-DOTA-NOC PET/CT image quality

Lei Xu, Can Cui, Rushuai Li, Rui Yang, Rencong Liu, Qingle Meng, Feng Wang

2022EJNMMI Research13 citationsDOIOpen Access PDF

Abstract

Abstract Background Bayesian penalized likelihood (BPL) algorithm is an effective way to suppress noise in the process of positron emission tomography (PET) image reconstruction by incorporating a smooth penalty. The strength of the smooth penalty is controlled by the penalization factor. The aim was to investigate the impact of different penalization factors and acquisition times in a new BPL algorithm, HYPER Iterative, on the quality of 68 Ga-DOTA-NOC PET/CT images. A phantom and 25 patients with neuroendocrine neoplasms who underwent 68 Ga-DOTA-NOC PET/CT were included. The PET data were acquired in a list-mode with a digital PET/CT scanner and reconstructed by ordered subset expectation maximization (OSEM) and the HYPER Iterative algorithm with seven penalization factors between 0.03 and 0.5 for acquisitions of 2 and 3 min per bed position (m/b), both including time-of-flight and point of spread function recovery. The contrast recovery (CR), background variability (BV) and radioactivity concentration ratio (RCR) of the phantom; The SUV mean and coefficient of variation (CV) of the liver; and the SUV max of the lesions were measured. Image quality was rated by two radiologists using a five-point Likert scale. Results The CR, BV, and RCR decreased with increasing penalization factors for four “hot” spheres, and the HYPER Iterative 2 m/b groups with penalization factors of 0.07 to 0.2 had equivalent CR and superior BV performance compared to the OSEM 3 m/b group. The liver SUV mean values were approximately equal in all reconstruction groups (range 5.95–5.97), and the liver CVs of the HYPER Iterative 2 m/b and 3 m/b groups with the penalization factors of 0.1 to 0.2 were equivalent to those of the OSEM 3 m/b group ( p = 0.113–0.711 and p = 0.079–0.287, respectively), while the lesion SUV max significantly increased by 19–22% and 25%, respectively (all p < 0.001). The highest qualitative score was attained at a penalization factor of 0.2 for the HYPER Iterative 2 m/b group (3.20 ± 0.52) and 3 m/b group (3.70 ± 0.36); those scores were comparable to or greater than that of the OSEM 3 m/b group (3.09 ± 0.36, p = 0.388 and p < 0.001, respectively). Conclusions The HYPER Iterative algorithm with a penalization factor of 0.2 resulted in higher lesion contrast and lower image noise than OSEM for 68 Ga-DOTA-NOC PET/CT, allowing the same image quality to be achieved with less injected radioactivity and a shorter acquisition time.

Topics & Concepts

Imaging phantomAlgorithmIterative reconstructionImage qualityMedicineNuclear medicineExpectation–maximization algorithmMathematicsArtificial intelligenceRadiologyComputer scienceImage (mathematics)StatisticsMaximum likelihoodMedical Imaging Techniques and ApplicationsRadiomics and Machine Learning in Medical ImagingRadiopharmaceutical Chemistry and Applications