Litcius/Paper detail

Comparison between modified wet suction and dry suction technique for endoscopic ultrasound‐guided fine‐needle biopsy in pancreatic solid lesions

Ting Tong, Li Tian, Minzi Deng, Yang Liu, Y F Yang, Hua Yin, Xiuyan Long, Shiyu Pan, Zhenyu Yang, Weiwei Luo, Kai Nie, Xiangrui Meng, Mengwei Xiao, Wu Xing, Chao Zhang, Xiaoyan Wang

2020Journal of Gastroenterology and Hepatology23 citationsDOI

Abstract

BACKGROUND AND AIM: Although endoscopic ultrasound-guided fine-needle biopsy is widely applied, there is no clear consensus on the optimal biopsy technique. We described a modified wet suction technique (MWEST) with the aim to compare the efficacy and safety between MWEST and the dry suction technique (DST). METHODS: In this prospective, randomized, crossover, single-blinded study, patients with suspected pancreatic malignancy were randomized to the DST (group A) or MWEST (group B) for the first pass, and the two techniques were performed alternately. The primary outcome was the comparison of specimen adequacy and diagnostic yield between the techniques. Secondary outcomes included the macroscopic visible core length, blood contamination of specimens, and adverse events of both techniques. RESULTS: From January 2019 to September 2019, 216 passes were performed in 50 patients. The specimen adequacy was significantly higher in "per-lesion" (P = 0.026), "per-pass" (cytology: P = 0.034; histology: P = 0.042), and first-pass analysis (P = 0.034) for MWEST than for DST. In diagnostic yield, MWEST showed significantly superior histological yield (P = 0.014) and first-pass analysis (κ: MWEST: 0.743 and DST: 0.519) compared with DST. The median macroscopic visible core lengths were 8 mm (interquartile range: 3.25-15 mm) and 10 mm (interquartile range: 5.25-15 mm) for DST and MWEST, respectively (P = 0.036). Blood contamination was significantly more serious in DST than in MWEST (cytology: P = 0.021; histology: P = 0.042). CONCLUSIONS: Endoscopic ultrasound-guided fine-needle biopsy with MWEST resulted in significantly better quality of specimen, histological, and first-pass diagnostic yields and comparable safety compared with the DST. MWEST is preferred for endoscopic ultrasound-guided fine-needle biopsy in pancreatic solid lesions.

Topics & Concepts

MedicineInterquartile rangeBiopsyEndoscopic ultrasoundSuctionFine-needle aspirationCytologyHistologyNuclear medicineMalignancyRadiologySurgeryPathologyEngineeringMechanical engineeringPancreatic and Hepatic Oncology ResearchPancreatitis Pathology and TreatmentGallbladder and Bile Duct Disorders
Comparison between modified wet suction and dry suction technique for endoscopic ultrasound‐guided fine‐needle biopsy in pancreatic solid lesions | Litcius