Long-length tomosynthesis and 3D-2D registration for intraoperative assessment of spine instrumentation
Xiaoxuan Zhang, Ali Uneri, Pengwei Wu, Michael D. Ketcha, Craig Jones, Yixuan Huang, Sheng-Fu Larry Lo, Patrick A. Helm, Jeffrey H. Siewerdsen
Abstract
PURPOSE: A system for long-length intraoperative imaging is reported based on longitudinal motion of an O-arm gantry featuring a multi-slot collimator. We assess the utility of long-length tomosynthesis and the geometric accuracy of 3D image registration for surgical guidance and evaluation of long spinal constructs. METHODS: A multi-slot collimator with tilted apertures was integrated into an O-arm system for long-length imaging. The multi-slot projective geometry leads to slight view disparity in both long-length projection images (referred to as 'line scans') and tomosynthesis 'slot reconstructions' produced using a weighted-backprojection method. The radiation dose for long-length imaging was measured, and the utility of long-length, intraoperative tomosynthesis was evaluated in phantom and cadaver studies. Leveraging the depth resolution provided by parallax views, an algorithm for 3D-2D registration of the patient and surgical devices was adapted for registration with line scans and slot reconstructions. Registration performance using single-plane or dual-plane long-length images was evaluated and compared to registration accuracy achieved using standard dual-plane radiographs. RESULTS: , equivalent to ∼2.5 s of fluoroscopy and comparable to other long-length imaging systems. Long-length scanning produced high-resolution tomosynthesis reconstructions, covering ∼12-16 vertebral levels. 3D image registration using dual-plane slot reconstructions achieved median target registration error (TRE) of 1.2 mm and 0.6° in cadaver studies, outperforming registration to dual-plane line scans (TRE = 2.8 mm and 2.2°) and radiographs (TRE = 2.5 mm and 1.1°). 3D registration using single-plane slot reconstructions leveraged the ∼7-14° angular separation between slots to achieve median TRE ∼2 mm and <2° from a single scan. CONCLUSION: The multi-slot configuration provided intraoperative visualization of long spine segments, facilitating target localization, assessment of global spinal alignment, and evaluation of long surgical constructs. 3D-2D registration to long-length tomosynthesis reconstructions yielded a promising means of guidance and verification with accuracy exceeding that of 3D-2D registration to conventional radiographs.