Outdoor PM<sub>2.5</sub> air filtration: optimising indoor air quality and energy

Evangelos Belias, Dusan Licina

2022Buildings and Cities17 citationsDOIOpen Access PDF

Abstract

Human inhalation exposure to fine particulate matter (PM<sub>2.5</sub>), including the PM<sub>2.5</sub> of outdoor origin, predominantly occurs indoors. To limit outdoor PM<sub>2.5</sub> penetration into buildings, ventilation standards often require the filtration of outdoor air with a minimum efficiency. Nevertheless, the PM<sub>2.5</sub> filter selection recommended by the standards is based on the annual average outdoor concentrations without considering seasonal or diurnal fluctuations. This could result in a waste of energy or elevated indoor PM<sub>2.5</sub> exposures. Representative outdoor PM<sub>2.5</sub> data from 37 cities worldwide in conjunction with a simulated office building are used to examine the impact of filtration strategies on indoor PM<sub>2.5</sub> levels and the fan’s energy consumption. Two energy-saving methods are tested: (1) the optimum filter selection that maintains the indoor PM<sub>2.5</sub> below the World Health Organization’s (WHO) air quality guidelines; and (2) the baseline filter recommended by standards in combination with a filter bypass. Relative to a standard recommended baseline case, the two applied methods could reduce energy demand by between 4% and 17%. This indicates that the outdoor air is over-filtered in the majority of the investigated cities. In cities with low-to-moderate outdoor PM<sub>2.5</sub> levels, using a filter bypass can be an effective energy conservation method without compromising PM<sub>2.5</sub> exposures indoors. <em><strong>Practice relevance</strong></em> Protecting building occupants from outdoor originating PM<sub>2.5</sub> without a high energy penalty is not a simple task. The majority of recommendations for ventilation system design typically do not consider temporal variation in outdoor PM<sub>2.5</sub>. This study’s data suggest that outdoor air filtration efficiencies required by building standards are not sufficient to protect the building occupants living in severely polluted areas. In these areas, outdoor air filtration should be supplemented with other measures to limit outdoor PM<sub>2.5</sub> penetration. In areas with low or intermittent outdoor PM<sub>2.5</sub> levels, bypassing the filter can significantly reduce the energy consumption from fans without compromising indoor air quality. The energy-saving potential increases with the increase of outdoor air quality. This study suggests that improved outdoor air filtration can be achieved by a stronger reliance on continuous outdoor air quality data recorded on site.

Topics & Concepts

Environmental scienceIndoor air qualityParticulatesAir quality indexAir filterVentilation (architecture)Environmental engineeringFiltration (mathematics)Energy consumptionFilter (signal processing)MeteorologyAtmospheric sciencesGeographyEngineeringPhysicsChemistryMathematicsStatisticsInletElectrical engineeringMechanical engineeringOrganic chemistryAir Quality and Health ImpactsAir Quality Monitoring and ForecastingNoise Effects and Management
Outdoor PM&lt;sub&gt;2.5&lt;/sub&gt; air filtration: optimising indoor air quality and energy | Litcius