Litcius/Paper detail

Evaluation of Shear Bond Strength of a Primer Incorporated Orthodontic Composite Resin: An In-Vitro Study

Rithika Joseph, Nausheer Ahmed, Abrar Younus A, K Ranjan R Bhat

2022Cureus14 citationsDOIOpen Access PDF

Abstract

C for 24 hours and debonded with a universal testing machine. The adhesive remnant index (ARI) was also evaluated. Statistical analysis was done using one-way ANOVA to compare the shear bond strength values among the three groups and Kruskal Wallis test was used for comparison of ARI scores. Results The SBS values in group A (11.60 ± 2.95 MPa), group B (9.44 ± 4.46 MPa) and group C (12.68 ± 6.25 MPa) were found to be comparable with no statistically significant difference. The ARI scores were also similar among the tested groups with the predominant site of bond failure being the bracket-adhesive interface indicating a safe bond-failure site. Conclusion GC Ortho Connect was found have clinically acceptable shear bond strength values that are comparable with that of self-etching primer and conventional bonding system. Therefore, it can be used effectively for saving the clinician's chairside time by reduction in the number of steps during bonding without compromising on the bond strength.

Topics & Concepts

AdhesiveUniversal testing machineBracketBond strengthDentistryPrimer (cosmetics)Composite numberShear strength (soil)MedicineOrthodonticsComposite materialMaterials scienceUltimate tensile strengthStructural engineeringChemistrySoil waterEnvironmental scienceEngineeringLayer (electronics)Organic chemistrySoil scienceDental materials and restorationsDental Research and COVID-19Orthodontics and Dentofacial Orthopedics