Litcius/Paper detail

Evaluating Diagnostic Accuracy and Inter-reader Agreement of the Prostate Imaging After Focal Ablation Scoring System

David G. Gelikman, Alexander P. Kenigsberg, Yan Mee Law, Enis C. Yılmaz, Stephanie A. Harmon, Sahil H. Parikh, Jason A. Hyman, Hannah Huth, Christopher Koller, Daniel Nethala, Charles Hesswani, Maria J. Merino, Sandeep Gurram, Peter L. Choyke, Bradford J. Wood, Peter Pinto, Barış Türkbey

2024European Urology Open Science24 citationsDOIOpen Access PDF

Abstract

Background and objective: Focal therapy (FT) is increasingly recognized as a promising approach for managing localized prostate cancer (PCa), notably reducing treatment-related morbidities. However, post-treatment anatomical changes present significant challenges for surveillance using current imaging techniques. This study aimed to evaluate the inter-reader agreement and efficacy of the Prostate Imaging after Focal Ablation (PI-FAB) scoring system in detecting clinically significant prostate cancer (csPCa) on post-FT multiparametric magnetic resonance imaging (mpMRI). Methods: ), and the system's efficacy in predicting in-field recurrence of csPCa, with a PI-FAB score cutoff of 3. Additional diagnostic metrics including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall accuracy were also evaluated. Key findings and limitations: = 0.56). Both radiologists achieved sensitivity of 93% in detecting csPCa, although specificity, PPVs, NPVs, and accuracy varied. Conclusions and clinical implications: The PI-FAB scoring system exhibited high sensitivity with moderate inter-reader agreement in detecting in-field recurrence of csPCa. Despite promising results, its low specificity and PPV necessitate further refinement. These findings underscore the need for larger studies to validate the clinical utility of PI-FAB, potentially aiding in standardizing post-treatment surveillance. Patient summary: Focal therapy has emerged as a promising approach for managing localized prostate cancer, but limitations in current imaging techniques present significant challenges for post-treatment surveillance. The Prostate Imaging after Focal Ablation (PI-FAB) scoring system showed high sensitivity for detecting in-field recurrence of clinically significant prostate cancer. However, its low specificity and positive predictive value necessitate further refinement. Larger, more comprehensive studies are needed to fully validate its clinical utility.

Topics & Concepts

MedicineProstate cancerProstateMagnetic resonance imagingRadiologyRetrospective cohort studyKappaBiopsyAblationNuclear medicineCancerSurgeryInternal medicineLinguisticsPhilosophyProstate Cancer Diagnosis and TreatmentProstate Cancer Treatment and ResearchAdvanced Radiotherapy Techniques