Comparison of outcomes of an 18-gauge vs 16-gauge ultrasound-guided percutaneous renal biopsy: a systematic review and meta-analysis
Tingting Zhan, Ali Lou
Abstract
While the 16-gauge needle for ultrasound-guided percutaneous renal biopsy offers improved efficacy in terms of a higher mean number of glomeruli and fewer required passes, it is associated with higher total complications. A judicious needle size selection that would consider patient-specific factors and risk-benefit ratio, is crucial for optimizing patient outcomes.
Topics & Concepts
MedicinePercutaneousUltrasoundBiopsyMeta-analysisPercutaneous biopsyRadiologyGauge (firearms)Renal biopsySurgeryInternal medicineArchaeologyHistoryRenal and Vascular PathologiesPediatric Urology and Nephrology StudiesKidney Stones and Urolithiasis Treatments