Litcius/Paper detail

X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study

Marc-Samir Guillot, Aymeric Rouchaud, Charbel Mounayer, Jérémy Tricard, Alexis Belgacem, Emilie Auditeau, Olivier Omraam, Laurent Fourcade, Quentin Ballouhey

2021Interactive Cardiovascular and Thoracic Surgery14 citationsDOIOpen Access PDF

Abstract

OBJECTIVES: To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS: From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia-Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS: Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (Pearson coefficient = 0.886; P = 0.033). CONCLUSIONS: Non-irradiant pectus deformity assessment is possible in clinical practice, replacing CT with MRI and 3D scanning as a possible readily-accessible monitoring tool.

Topics & Concepts

MedicineMagnetic resonance imagingConcordanceNuclear medicineCorrelation coefficientPearson product-moment correlation coefficientPectus excavatumRadiologyDeformityCorrelationSurgeryMathematicsStatisticsInternal medicineGeometryPectus Deformity Diagnosis and TreatmentScoliosis diagnosis and treatmentCongenital gastrointestinal and neural anomalies
X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: a preliminary study | Litcius