Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16)

Rubina Shah, A.Y. Finlay, Sam Salek, Harris Allen, S J Nixon, Mark Nixon, Kennedy Otwombe, Faraz M Ali, John R Ingram

2024Journal of Patient-Reported Outcomes15 citationsDOIOpen Access PDF

Abstract

BACKGROUND: The FROM-16 is a generic family quality of life (QoL) instrument that measures the QoL impact of patients' disease on their family members/partners. The study aimed to assess the responsiveness of FROM-16 to change and determine Minimal Important Change (MIC). METHODS: Responsiveness and MIC for FROM-16 were assessed prospectively with patients and their family members recruited from outpatient departments of the University Hospital Wales and University Hospital Llandough, Cardiff, United Kingdom. Patients completed the EQ-5D-3L and a global severity question (GSQ) online at baseline and at 3-month follow-up. Family members completed FROM-16 at baseline and a Global Rating of Change (GRC) in addition to FROM-16 at follow-up. Responsiveness was assessed using the distribution-based (effect size-ES, standardized response mean -SRM) and anchor-based (area under the receiver operating characteristics curve ROC-AUC) approaches and by testing hypotheses on expected correlation strength between FROM-16 change score and patient assessment tools (GSQ and EQ-5D). Cohen's criteria were used for assessing ES. The AUC ≥ 0.7 was considered a good measure of responsiveness. MIC was calculated using anchor-based (ROC analysis and adjusted predictive modelling) and distribution methods based on standard deviation (SD) and standard error of the measurement (SEM). RESULTS: Eighty-three patients with 15 different health conditions and their relatives completed baseline and follow-up questionnaires and were included in the responsiveness analysis. The mean FROM-16 change over 3 months = 1.43 (SD = 4.98). The mean patient EQ-5D change over 3 months = -0.059 (SD = 0.14). The responsiveness analysis showed that the FROM-16 was responsive to change (ES = 0.2, SRM = 0.3; p < 0.01). The ES and SRM of FROM-16 change score ranged from small (ES = 0.2; SRM = 0.3) for the distribution-based method to large (ES = 0.8, SRM = 0.85) for anchor-based methods. The AUC value was above 0.7, indicating good responsiveness. There was a significant positive correlation between the FROM-16 change scores and the patient's disease severity change scores (p < 0.001). The MIC analysis was based on data from 100 family members of 100 patients. The MIC value of 4 was suggested for FROM-16. CONCLUSIONS: The results of this study confirm the longitudinal validity of FROM-16 which refers to the degree to which an instrument is able to measure change in the construct to be measured. The results yield a MIC value of 4 for FROM-16. These psychometric attributes of the FROM-16 instrument are useful in both clinical research as well as clinical practice.

Topics & Concepts

Receiver operating characteristicMedicineQuality of life (healthcare)Standard errorPhysical therapyMinimal clinically important differenceInternal medicineStatisticsRandomized controlled trialMathematicsNursingFamily and Patient Care in Intensive Care UnitsPatient Satisfaction in HealthcareFamily Caregiving in Mental Illness
Responsiveness and minimal important change of the Family Reported Outcome Measure (FROM-16) | Litcius