Litcius/Paper detail

Five-Year Clinical Outcome of the Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent Compared to the Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: From the SORT OUT VII Trial

Kirstine Nørregaard Hansen, Lisette Okkels Jensen, Michael Mæng, Martin Kirk Christensen, Manijeh Noori, Johnny Kahlert, Lars Jakobsen, Anders Junker, Phillip Freeman, Julia Ellert‐Gregersen, Bent Raungaard, Christian Juhl Terkelsen, Karsten Tange Veien, Evald Høj Christiansen

2023Circulation Cardiovascular Interventions14 citationsDOIOpen Access PDF

Abstract

BACKGROUND: Biodegradable polymer drug-eluting stents were developed to improve safety and efficacy outcomes for patients undergoing percutaneous coronary intervention. However, few long-term follow-up efficacy studies are available. The study sought to investigate 5-year results from the SORT OUT VII trial (Scandinavian Organization for Randomized Trials With Clinical Outcome) comparing the biodegradable polymer ultrathin-strut sirolimus-eluting Orsiro stent (O-SES) versus the biodegradable polymer biolimus-eluting Nobori stent (N-BES). METHODS: This registry-based, randomized, multicenter, single-blinded, noninferiority trial compared O-SES and N-BES in an all-comer population. The composite primary end point, target lesion failure, consisted of cardiac death, myocardial infarction related to the target lesion, or target lesion revascularization within 1 year. Follow-up was extended to 5 years. RESULTS: Five-year follow-up was completed for 2521 patients (99.8%). Five-year target lesion failure did not differ between O-SES (12.4%) and N-BES (13.1%; rate ratio [RR], 0.94 [95% CI, 0.75-1.18]). Cardiac death (RR, 0.95 [95% CI, 0.67-1.34]), target myocardial infarction (RR, 1.14 [95% CI, 0.76-1.71]), target lesion revascularization (RR, 0.90 [95% CI, 0.67-1.21]), and definite stent thrombosis rates (RR, 0.73 [95% CI, 0.41-1.33]) did not differ significantly between the 2 stents. Within the first year, definite ST was significantly lower for O-SES (0.4%) compared to N-BES (1.2%; RR, 0.33 [95% CI, 0.12-0.92]), but no difference was from 1 through 5 years: O-SES 1.2% and N-BES 0.9% (RR, 1.28 [95% CI, 0.58-2.82]). CONCLUSIONS: Five years after treatment with biodegradable polymer stents, target lesion failure did not differ among O-SES and N-BES. Definite stent thrombosis was less often seen within the first year in the O-SES but the difference was not maintained after 5 years. REGISTRATION: URL: https://clinicaltrials.gov; Unique identifier: NCT01879358.

Topics & Concepts

MedicinePercutaneous coronary interventionSirolimusStentBiodegradable polymerSurgeryCardiologyPolymerMyocardial infarctionOrganic chemistryChemistryCoronary Interventions and DiagnosticsCardiac Valve Diseases and TreatmentsAortic aneurysm repair treatments
Five-Year Clinical Outcome of the Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent Compared to the Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention: From the SORT OUT VII Trial | Litcius