Litcius/Paper detail

Assessment of Pyloric Sphincter Physiology Using Functional Luminal Imaging Probe in Healthy Volunteers

Nitin Jagtap, Rakesh Kalapala, D. Nageshwar Reddy

2020Journal of Neurogastroenterology and Motility28 citationsDOIOpen Access PDF

Abstract

Background/Aims: The functional luminal imaging probe (FLIP) can measure tissue distensibility and geometric changes through volumetric distention. The esophagogastric junction has been well studied using EndoFLIP, studies on pylorus are lacking. We aim to study biomechanical properties of pylorus using EndoFLIP to create normative data. Methods: We performed a prospective study of 20 healthy volunteers (ages, 18-54 years; 10 men) who underwent pylorus evaluation using 12- cm FLIP placed across the pyloric sphincter. FLIP data were analyzed using FLIP planimetry plots at baseline and after administration of hyoscine butyl bromide injection. Results: < 0.05). Conclusion: The normative values can be used as reference values for pyloric distensibility. This reference can be used in studies of related to pyloric diseases such as gastroparesis.

Topics & Concepts

MedicineSphincterFunctional imagingPhysiologyInternal medicineAnatomyRadiologyGastrointestinal motility and disordersEsophageal Cancer Research and TreatmentGastroesophageal reflux and treatments