Determining a minimum set of variables for machine learning cardiovascular event prediction: results from REFINE SPECT registry

Richard Ríos, Robert J.H. Miller, Lien-Hsin Hu, Yuka Otaki, Ananya Singh, Márcio A. Diniz, Tali Sharir, Andrew J. Einstein, Mathews B. Fish, Terrence D. Ruddy, Philipp A. Kaufmann, Albert J. Sinusas, Edward J. Miller, Timothy M. Bateman, Sharmila Dorbala, Marcelo F. DiCarli, Serge Van Kriekinge, Paul Kavanagh, Tejas Parekh, Joanna X. Liang, Damini Dey, Daniel S. Berman, Piotr J. Slomka

2021Cardiovascular Research41 citationsDOIOpen Access PDF

Abstract

AIMS: Optimal risk stratification with machine learning (ML) from myocardial perfusion imaging (MPI) includes both clinical and imaging data. While most imaging variables can be derived automatically, clinical variables require manual collection, which is time-consuming and prone to error. We determined the fewest manually input and imaging variables required to maintain the prognostic accuracy for major adverse cardiac events (MACE) in patients undergoing a single-photon emission computed tomography (SPECT) MPI. METHODS AND RESULTS: This study included 20 414 patients from the multicentre REFINE SPECT registry and 2984 from the University of Calgary for training and external testing of the ML models, respectively. ML models were trained using all variables (ML-All) and all image-derived variables (including age and sex, ML-Image). Next, ML models were sequentially trained by incrementally adding manually input and imaging variables to baseline ML models based on their importance ranking. The fewest variables were determined as the ML models (ML-Reduced, ML-Minimum, and ML-Image-Reduced) that achieved comparable prognostic performance to ML-All and ML-Image. Prognostic accuracy of the ML models was compared with visual diagnosis, stress total perfusion deficit (TPD), and traditional multivariable models using area under the receiver-operating characteristic curve (AUC). ML-Minimum (AUC 0.798) obtained comparable prognostic accuracy to ML-All (AUC 0.799, P = 0.19) by including 12 of 40 manually input variables and 11 of 58 imaging variables. ML-Reduced achieved comparable accuracy (AUC 0.796) with a reduced set of manually input variables and all imaging variables. In external validation, the ML models also obtained comparable or higher prognostic accuracy than traditional multivariable models. CONCLUSION: Reduced ML models, including a minimum set of manually collected or imaging variables, achieved slightly lower accuracy compared to a full ML model but outperformed standard interpretation methods and risk models. ML models with fewer collected variables may be more practical for clinical implementation.

Topics & Concepts

Myocardial perfusion imagingArtificial intelligenceReceiver operating characteristicSingle-photon emission computed tomographyMachine learningComputer sciencePerfusion scanningMaceMedicineNuclear medicinePerfusionStatisticsMathematicsRadiologyInternal medicineConventional PCIMyocardial infarctionCardiac Imaging and DiagnosticsCoronary Interventions and DiagnosticsAcute Myocardial Infarction Research
Determining a minimum set of variables for machine learning cardiovascular event prediction: results from REFINE SPECT registry | Litcius