Litcius/Paper detail

The feasibility of half-dose contrast-enhanced scanning of brain tumours at 5.0 T: a preliminary study

Zhiyong Jiang, Wenbo Sun, Dan Xu, Hao Mei, Jianmin Yuan, Xiaopeng Song, Chao Ma, Haibo Xu

2024BMC Medical Imaging7 citationsDOIOpen Access PDF

Abstract

PURPOSE: This study investigated and compared the effects of Gd enhancement on brain tumours with a half-dose of contrast medium at 5.0 T and with a full dose at 3.0 T. METHODS: Twelve subjects diagnosed with brain tumours were included in this study and underwent MRI after contrast agent injection at 3.0 T (full dose) or 5.0 T (half dose) with a 3D T1-weighted gradient echo sequence. The postcontrast images were compared by two independent neuroradiologists in terms of the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and subjective image quality score on a ten-point Likert scale. Quantitative indices and subjective quality ratings were compared with paired Student's t tests, and interreader agreement was assessed with the intraclass correlation coefficient (ICC). RESULTS: A total of 16 enhanced tumour lesions were detected. The SNR was significantly greater at 5.0 T than at 3.0 T in grey matter, white matter and enhanced lesions (p < 0.001). The CNR was also significantly greater at 5.0 T than at 3.0 T for grey matter/tumour lesions, white matter/tumour lesions, and grey matter/white matter (p < 0.001). Subjective evaluation revealed that the internal structure and outline of the tumour lesions were more clearly displayed with a half-dose at 5.0 T (Likert scale 8.1 ± 0.3 at 3.0 T, 8.9 ± 0.3 at 5.0 T, p < 0.001), and the effects of enhancement in the lesions were comparable to those with a full dose at 3.0 T (7.8 ± 0.3 at 3.0 T, 8.7 ± 0.4 at 5.0 T, p < 0.001). All subjective scores were good to excellent at both 5.0 T and 3.0 T. CONCLUSION: Both quantitative and subjective evaluation parameters suggested that half-dose enhanced scanning via 5.0 T MRI might be feasible for meeting clinical diagnostic requirements, as the image quality remains optimal. Enhanced scanning at 5.0 T with a half-dose of contrast agents might benefit patients with conditions that require less intravenous contrast agent, such as renal dysfunction.

Topics & Concepts

White matterMedicineNuclear medicineIntraclass correlationGrey scaleGrey matterContrast (vision)Magnetic resonance imagingRadiologyPhysicsComputer visionComputer scienceOpticsClinical psychologyPsychometricsMRI in cancer diagnosisLanthanide and Transition Metal ComplexesUltrasound and Hyperthermia Applications
The feasibility of half-dose contrast-enhanced scanning of brain tumours at 5.0 T: a preliminary study | Litcius