Litcius/Paper detail

Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study

Sophie Geyl, Benjamin Redelsperger, Clara Yzet, Bertrand Napoléon, Romain Legros, Martin Dahan, Hugo Lepetit, Claire Ginestet, Jérémie Jacques, Jérémie Albouys

2023Endoscopic Ultrasound27 citationsDOIOpen Access PDF

Abstract

Background: EUS-guided choledoco-duodenostomy using electrocautery-enhanced lumen-apposing metal stents (ECE-LAMS) is becoming the gold standard in case of endoscopic retrograde cholangio-pancreatography failure for distal malignant obstruction. Long-term data in larger samples are lacking. Methods: This was a prospective monocentric study including all patients who underwent EUS-guided choledochoduodenostomy (CDS) between September 2016 and December 2021. The primary endpoint was the rate of biliary obstruction during follow-up. Secondary endpoints were technical and clinical success rates, adverse event rates, and identification of risk factors for biliary obstruction. Results: One hundred and twenty-three EUS-guided CDS using ECE-LAMS were performed at Limoges University Hospital were performed during the study period and included in the study. The main cause of obstruction was pancreatic adenocarcinoma in 91 (74.5%) cases. The technical and clinical success rates were 97.5% and 91%, respectively. Twenty patients (16.3%) suffered from biliary obstructions during a mean follow-up of 242 days. The clinical success rate for endoscopic desobstruction was 80% (16/20). In uni- and multivariate analyses, only the presence of a duodenal stent (odds ratio [OR]: 3.6, 95% confidence interval [CI] 95%: 1.2-10.2; P = 0.018) and a bile duct thinner than 15 mm (OR: 3.9, CI 95%: 1.3-11.7; P = 0.015) were the significant risk factors for biliary obstruction during the follow-up. Conclusion: Obstruction of LAMS occurred in 16.3% of cases during follow-up and endoscopic desobstruction is efficacious in 80% of cases. The presence of duodenal stent and a bile duct thinner than 15 mm are the risk factors of obstruction. Except in these situation, EUS-CDS with ECE-LAMS could be proposed in the first intent in case of distal malignant obstruction.

Topics & Concepts

MedicineStentOdds ratioClinical endpointConfidence intervalProspective cohort studyEndoscopic ultrasoundLumen (anatomy)Bile ductSurgeryCommon bile ductGastroenterologyInternal medicineClinical trialGallbladder and Bile Duct DisordersEsophageal and GI PathologyPancreatic and Hepatic Oncology Research
Risk factors for stent dysfunction during long-term follow-up after EUS-guided biliary drainage using lumen-apposing metal stents: A prospective study | Litcius