Diagnostic Accuracy of CT for the Detection of Hepatic Steatosis: A Systematic Review and Meta-Analysis
Maryam Haghshomar, Dominic Antonacci, Andrew D. Smith, Sarang Thaker, Frank H. Miller, Amir A. Borhani
Abstract
statistic, and meta-regression to explore potential sources of heterogeneity. When available, mean liver attenuation, liver-spleen attenuation difference, liver to spleen attenuation ratio, and the DECT-derived fat fraction for hepatic steatosis diagnosis were assessed. Results Forty-two studies (14 186 participants) were included. NCCT had a sensitivity and specificity of 72% and 88%, respectively, for steatosis (>5% fat at biopsy) detection and 82% and 94% for at least moderate steatosis (over 20%-33% fat at biopsy) detection. CECT had a sensitivity and specificity of 66% and 90% for steatosis detection and 68% and 93% for at least moderate steatosis detection. DECT had a sensitivity and specificity of 85% and 88% for steatosis detection. In the subgroup analysis, the sensitivity and specificity for detecting steatosis were 80% and 99% for CECT and 84% and 93% for DECT. There was heterogeneity among studies focusing on CECT and DECT. Liver attenuation less than 40-45 HU, liver-spleen attenuation difference less than -5 to 0 HU, and liver to spleen attenuation ratio less than 0.9-1 achieved high specificity for detection of at least moderate steatosis. Conclusion NCCT showed high performance for detection of at least moderate steatosis. © RSNA, 2024